Skip to content
Loading map…

Hampton Inn & Suites - Swimming Pool

3916 84 Avenue Leduc AB T9E 8M6 · Aquatic Facility

Inspection summary

Hampton Inn & Suites - Swimming Pool has been inspected 10 times by Alberta Health Services (Environmental Public Health) since November 28, 2023. The most recent inspection, on October 8, 2026, found no infractions.

1 of 10 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 11 times across 9 separate inspections, most recently on October 6, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 2 times across 2 separate inspections, most recently on November 18, 2024. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

10 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • ** Missing floating weir gate in one of the skimmers.ACTION REQUIRED1) Install the missing skimmer floating weir gate to maximize surface skimming of the pool water.
  3. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Turnover = 14,001gals/60gpm/60 = 3.9 hoursACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 390cfu HPC isolated from a sample collected in October 29.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Turnover = 14,001gals/60gpm/60 = 3.9 hoursACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  5. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Turnover = 14,001gals/60gpm/60 = 3.9 hoursACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  6. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 390HPC present in a sample submitted on July 9/25.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Turnover = 14,001gals/60gpm/60 = 3.9 hoursACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  7. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Turnover = 14,001gals/60gpm/60 = 3.9 hoursACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  8. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. ACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
  9. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Filter surface area = 4.9 sq.ft- Volume = 14200Gals- Flow rate = 55gpmTurnover = 14200gals/55gpm/60 = 4.3 hoursFiltration rate = 55gpm/4.9sq.ft = 11.22gpm/sq.ftACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize surface skimming of the pool water.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan has been submitted, reviewed and deemed not to be in compliance. RECOMMENDED COMPLIANCE OPTIONS:1) Install unblockable covers OR2) Install a secondary anti-entrapment device such as:- A Safety Vacuum Release System (SVRS) or- An Automatic pump shut off system.
  10. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Flappers/floating weirs missing from the skimmers. - Filter surface area = 4.9 sq.ft- Volume = 14200Gals- Flow rate = 55gpmTurnover = 14200gals/55gpm/60 = 4.3 hoursFiltration rate = 55gpm/4.9sq.ft = 11.22gpm/sq.ftACTION REQUIRED1) Install flappers/ floating weirs in the skimmers to maximize skimming of the pool water
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan has been submitted, reviewed and deemed not to be in compliance. The following compliance options were recommended to the operator:1) Install an unblockable cover OR2) Install a secondary anti-entrapment device such as:- A Safety Vacuum Release System (SVRS) or- An Automatic pump shut off

Nearby inspected facilities

Own this business? Add a badge to your website