Hampton Inn - Swimming Pool

100 - 950 Emerald Drive Sherwood Park AB T8H 0W6 · Aquatic Facility

11 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 130 on the lab report. Clean and resample.
  2. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Initial flow rate was observed to be 80 degrees Celsius. Sand filter is a TR100 filter medium surface area 4.91 sq.ft. Max flow rate for filter is 74 gpm. Operator reduced flow rate to 70 gpm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow of the water was not being maximized through the skimmers. This was corrected by limiting the flow to the main drain to 10% and while leaving the skimmer valves fully opened.The water surface was coming above the internal lip of the skimmers. This was adjusted by lowering the volume of the pool an inch.
  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Filter Maximum Flow Rate is 74 GPM.Pool operating at 80 GPM.Reduce flow rate to operator bellow legislative maximum of 74 pgm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Water Flow was not being maximized through the skimmers. Valves were adjusted to maximize flow through the skimmers and reduce the flow to the main drain.
  5. Monitoring Inspection

    0 infractions

  6. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • From previous visit: The alarm light was on at the automated controller panel. Operator reported the alarm was on due to high chlorine reading in the swimming pool. Free chlorine was then measured at 3.18 ppm. - Operator reported they will consult pool maintenance services to assess and remedy alarm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • From previous visit: The filtration rate of the swimming pool was calculated at 16.29 gpm/ft. sq. - Ensure the filtration rate does not exceed the maximum rate of 15 gpm/ft. sq. Adjust the pump to ensure the flow rate of the swimming pool does not exceed 74 GPM to maintain a filtration rate of 15gpm/ft. sq. or less.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An update copy of the anti-entrapment plan needs to be submitted to AHS- EPH. Safety covers appear to have been replaced on August 26,2024.
  7. Monitoring Inspection

    5 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The filtration rate of the swimming pool was calculated at 16.29 gpm/ft. sq. - Ensure the filtration rate does not exceed the maximum rate of 15 gpm/ft. sq. Adjust the pump to ensure the flow rate of the swimming pool does not exceed 74 GPM to maintain a filtration rate of 15gpm/ft. sq. or less.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent to the shower. - Replace the weir door to ensure proper skimmer function.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The alarm light was on at the automated controller panel. Operator reported the alarm was on due to high chlorine reading in the swimming pool. Free chlorine was then measured at 3.18 ppm. - Operator reported they will consult pool maintenance services to assess and remedy alarm.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The following submerged suction outlets were expired as per the anti-entrapment plan and have not been recently replaced as per operator: - S-MD1. WGX103213LV2. Installed June 1, 2015. Expired: Installed June 1, 2022.- S-MD2. WGX103213LV2. Installed June 1, 2015. Expired: Installed June 1, 2022.**Replace the submerged suction outlet covers as soon as possible due to expiry. Operator scheduled replacement for Monday, August 26th, 2024 and will close the pool during replacement. No damage, cracking, or screws missing to submerged suction outlets at the time of inspection. Anti-entrapment devices are critical pieces of equipment that must be ANSI/APSP-16 2011 compliant, installed according to manufacturer's specifications, maintained in good working order, be replaced before expiration, and follow all requirements set out in the Pool Standards, July 2014 (Amended January 2018); AR 204/2014 s 23.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The plastic within the swimming pool skimmer devices was separating above the water level leaving gaps that may leak water and/or harbour microbial growth. - Seal, repair, or replace skimmer devices to remove open gaps.
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample result; T.C presentIncrease Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water, resample as soon as possible.
  10. Monitoring Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample report for sample submitted on Sept 20, 2023, showed the presence of total coliforms.