Skip to content
Loading map…

Lodges At Canmore Phase I (Wolf Lodge) - Swimming Pool

107 Montane Road Canmore AB T1W 3J2 · Aquatic Facility

Inspection summary

Lodges At Canmore Phase I (Wolf Lodge) - Swimming Pool has been inspected 8 times by Alberta Health Services (Environmental Public Health) since December 11, 2024. The most recent inspection, on October 7, 2026, recorded 1 infraction.

None of the 8 inspections on record were free of infractions. In the past 12 months there were 3 inspections with 7 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 6 separate inspections, most recently on October 7, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on December 11, 2024. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 7 times across 7 separate inspections, most recently on June 15, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 7 times across 7 separate inspections, most recently on June 15, 2026. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

8 inspections

  1. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • If the flow meter is accurate for filter #2 (float appeared to be stuck), the flow rate is being exceeded through the filter. Maximum flow rate for the filter is 74gpm/279LPM; flow meter was reading 300LPM.
  2. Risk Management Inspection

    2 infractions

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  3. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken on June 5/26 was not tested as it was dropped off after the lab had closed for the weekend. New sample to be submitted as soon as possible this week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No water sample was submitted the week of May 25/26. A water sample is required to be submitted each week.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  4. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Thursday September 25th, 2025, had an HPC of 140 CFU/ml. - Operators were informed to treat and re-sample.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  5. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 15, 2025 water sample was not tested as there was not time of collection on the requisition form. Resample to be submitted.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  6. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • December 27, 2024 water sample was not tested. Resample to be submitted.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  7. Risk Management Inspection

    2 infractions

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.
  8. Monitoring Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No water sample was submitted the week of December 2-6, 2024.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Cyanuric acid level was measured at 56ppm. Backwash was done to remove some water from the pool and fresh water added. When cyanuric acid level re-measured was at 49ppm.Cyanuric acid level is be kept at 50ppm or less.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Cyanuric acid level is currently not being measured as ran out of the chemicals needed for testing. Obtain chemicals needed to test cyanuric acid level and ensure it is tested at least once a week, particularly after cyanuric acid is added.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan needs to be updated as new main drain covers were installed since the plan was written as well a new circulation pump was installed and some of the required questions on the plan were left blank.

Nearby inspected facilities