Skip to content
Loading map…

Renfrew Aquatic & Recreation Centre - Whirlpool

810 13 Avenue NE Calgary AB T2E 8A1 · Aquatic Facility

17 inspections

  1. Monitoring Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Drain covers have been replaced but anti-entrapment template has not been updated.-Update anti-entrapment plan
  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample 25ES-365E00272, collected on 31/12/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample 25ES-365E00272, collected on 31/12/2025, had a HPC of 290 CFU/mL.Treat and resample.
  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated from sample taken Nov 12.-Treat and resample
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample (25ES-204E00520) collected on July 23rd, 2025, was rejected by the lab as the sample was received without an identification sticker on the bottle. Please submit a new water sample for the whirlpool.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample (25ES-190E00352) collected on July 6th, 2025, was rejected by the lab as the sample was received at the lab more than 24 hours after collection. Please submit a new water sample for the whirlpool.
  9. Monitoring Inspection

    0 infractions

  10. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Hot tub tested positive for pseudomonas. Shock, dump, scrub and resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • combined chlorine manual measured 4.88ppm. See violation regarding floating weir. Deep clean hot. Recommend dump and scrub.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Floating weirs in hot tub had a heavy build up of scum and strong odor. Thoroughly clean entire hot tub.
  11. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water samples tested positive for Pseudomonas. Shock, dump and scrub. Resubmit sample on monday.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water samples tested 410cfu/ml HPC.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • combined chlorine manual measured 4.88ppm. See violation regarding floating weir. Deep clean hot. Recommend dump and scrub.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Floating weirs in hot tub had a heavy build up of scum and strong odor. Thoroughly clean entire hot tub.
  12. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • combined chlorine manual measured 4.88ppm. See violation regarding floating weir. Deep clean hot. Recommend dump and scrub.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Floating weirs in hot tub had a heavy build up of scum and strong odor. Thoroughly clean entire hot tub.
  13. Risk Management Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • combined chlorine manual measured 4.88ppm. See violation regarding floating weir. Deep clean hot. Recommend dump and scrub.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Floating weirs in hot tub had a heavy build up of scum and strong odor. Thoroughly clean entire hot tub.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Several taylor reagents expired 2022/2023. Replace expired reagents. Monitor expiry dates regularly.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan is missing certificate of compliance for drains and second page of plans that indicate drain max flow and installation/expiry.
  14. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • combined chlorine manual measured 4.88ppm. See violation regarding floating weir. Deep clean hot. Recommend dump and scrub.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Floating weirs in hot tub had a heavy build up of scum and strong odor. Thoroughly clean entire hot tub.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Several taylor reagents expired 2022/2023. Replace expired reagents. Monitor expiry dates regularly.
  15. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sept 6 2023 water sample has TC present. Treat and resample.
  16. Risk Management Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas present.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC measured 110 cfu/ml
  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present 170 cfu/ml