The Glencoe Club - Indoor Whirlpool

636 29 Avenue SW Calgary AB T2S 0P1 · Aquatic Facility

8 inspections

  1. Monitoring Inspection

    0 infractions

  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Sample collected on February 17, 2026 not tested, because there was no identification number on the bottle.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  3. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample received on October 1, 2025 was not processed as collection date was September 24, 2025.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  4. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  5. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on June 10/25 had HPC 130 cfu/ml. - Submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  6. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on March 18/25 had Pseudomonas isolated and HPC > 57000 cfu/ml. - Treat the whirlpool water and submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  7. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 43 mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
  8. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity too low and measured at 25mg/L.-Ensure water alkalinity is within required range of >60mg/L to <180mg/L.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • ** Repeat violation **VIOLATION: - The submerged suction outlet covers expired as of May 15, 2022.COMPLETE THE FOLLOWING: - Replace the expired drain covers.- Ensure to follow all manufacturer's instructions for use. ****CITED NOV 1ST 2023****Anti-entrapment plan was not available for assessment. The plan submitted in 2019 shows that the submerged suction outlet cover expired on May 15th, 2022.Action Required.- Please update and provide a copy of anti-entrapment plan. -Replace expired suction outlet covers and provide a copy of the certificate of compliance.