The Juniper Hotel & Bistro - Whirlpool
1 Juniper Way Banff AB T1L 1E1 · Aquatic Facility
7 inspections
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday October 27th, 2025, was not processed by the lab. - Missing ID sticker on the bottle, operators were informed to submit a re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Tuesday August 5th, 2025, was not processed by the lab. - Missing time of collection on the form, operators were informed to submit a re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Jet flow meter was broken, unable to get an accurate reading. - Please repair the flow meter, ensure jet flow is within the allowed range for the drain covers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday June 24th, 2024, had an HPC of 550 cfu/ml. - Operators were informed to treat and re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Initial Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automatic controller was set to maintain pH at 7.3; manually measured from pool basin at 7.0. Ensure controller is calibrated to manual readings.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate of recirculation pump reaching 80gpm; this would exceed the filter capacity of 61gpm. Plan review recommended that flow rate be no more than 48gpm (minimum 36gpm) due to the pool only having one skimmer (throttle back flow from main drain).
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?