TownePlace Suites Fort McMurray - Pool
321 Sakitawaw Trail Fort McMurray AB T9H 5E7 · Aquatic Facility
20 inspections
- Risk Management Inspection
1 infraction
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operator indicated that they do not have the Pool Operator Certificate and management has plans to ensure the course is taken. Pool operator indicated that in the interim a certified pool operator in the next hotel is able to help. Ensure that a pool operator certificate is obtained and a copy of the certificate is provided to the public health inspector for review.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was measured at 34ppm and not within the required range (60-180 ppm).Ensure that the chemical water parameters meet the required parameters indicated in the Pool Standards.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operator indicated that they do not have the Pool Operator Certificate and management has plans to ensure the course is taken. Pool operator indicated that in the interim a certified pool operator in the next hotel is able to help. Ensure that a pool operator certificate is obtained and a copy of the certificate is provided to the public health inspector for review.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Filtration rate was measured at 18.3 GPM/sq ft, which was above the required maximum filtration rate of 15 GPM/sq ft. Investigate and ensure that the maximum filtration rate of a high rate sand filter is below 15 GPM/sq ft.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
4 infractions
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Water clarity was observed poor and dust like particles floating on the surface of the water. Operator indicated the circulation of the water was not consistently working. Investigate and ensure that the circulation system including the filtration and disinfection systems are functional.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- Debris including hair, gum, and hair was observed in the gutter drain between the emergency exit and pool. Clean the gutter drain. It is recommended to clean increase the cleaning frequency of the gutter drain.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Suction outlet covers were stated expired on the Anti-entrapment plans and operator stated it has not been changed.Outlet covers were observed in free of cracks at the time of inspection.Replace the suction outlet covers and update the anti-entrapment plans.Provide PHI with specifications of the obtained suction outlet covers.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Records of the manual temperature water reading and automatic chemical readings are not kept.Ensure that operating records are maintained and kept, including pool water temperature and automatic chemical readings.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The latest water sample had an unsatisfactory result with heterotrophic plate count of 600 CFU/mL.Facility operator was instructed to raise the free available chlorine, run the water through the circulation system for at least 4-6 hours, adjust the water chemistry, and resample.Note: Resample was taken on July 3, 2024.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water had a heterotrophic plate count was at 600 CFU/mL.Facility operator was instructed to raise the free available chlorine, run the water through the circulation system for at least 4-6 hours, adjust the water chemistry, and resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.May 10, 2024 update: Automated system will be replaced with a new and different system. PHI will be updated on the installation and operation date of the new system.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.May 10, 2024 update: Automated system will be replaced with a new and different system. PHI will be updated on the installation and operation date of the new system.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Heterotrophic plate count resulted in >57000 CFU/mL.Pool operator was instructed to superchlorinate to 10ppm, maintaining pH around 7.2 for 4-6 hours. Then balance the pool water chemical parameters before allowing bathers back in. Operator was directed to resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.April 16, 2024 update: maintenance and service had been attempted but the automated system is still not functioning.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.April 16, 2024 update: maintenance and service had been attempted but the automated system is still not functioning.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Operators stated this has been ongoing for the last 2 months. Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Dec 12, 2023 sample result indicated.HPC - 340 CFU/mLSpoke with Daniel A., pool operator. He stated that the pool was super chlorinated on Dec 17, 2023. They had not experienced any fecal contamination or other incidents last week and over the weekend. Pool chemistry parameter measurements for Dec 18, 2023:TC - 6.15ppmFC - 0.56ppmTA - 129 ppmpH - 7.5Instructed pool operator to increase chlorine levels and rebalance after a turnover period.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course. Update: Pool operator indicated that he and other staff have enrolled and started a pool operator training program. The courses will be completed by December 2023.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Dec 12, 2023 sample result indicated.HPC - 340 CFU/mLSpoke with Daniel A., pool operator. He stated that the pool was super chlorinated on Dec 17, 2023. They had not experienced any fecal contamination or other incidents last week and over the weekend. Pool chemistry parameter measurements for Dec 18, 2023:TC - 6.15ppmFC - 0.56ppmTA - 129 ppmpH - 7.5Instructed pool operator to increase chlorine levels and rebalance after a turnover period.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined Chlorine was measured 2.28Operators stated pool had not been balanced before inspection. It was discussed operators will balance the water chemistry and forward the information by email.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated Hayward system was not function properly.Operators stated this has been ongoing for the last 2 months. Water chemistry has been balanced manually. Repair or replace the automated system and ensure it is functioning properly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC at 3210 cfu/mLPool operator was instructed of sample result. Operator will super chlorinate for a full turnover period and re-balance water chemistry. Operator will resample next week Tuesday.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course. Update: Pool operator indicated that he and other staff have enrolled and started a pool operator training program. The courses will be completed by December 2023.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course. Update: Pool operator indicated that he and other staff have enrolled and started a pool operator training program. The courses will be completed by December 2023.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC at 530 cfu/ml.Pool operator was instructed to superchlorinate to 10ppm, maintaining pH around 7.2 for a full turnover period, which is about 3.5 hours. Then balance the pool water chemical parameters before allowing bathers back in. Operator was directed to resample for next week.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Heterotrophic plate count (HPC) of sample submitted measured greater than 1740 cfu/ml.Operator was directed to resample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combine chlorine levels are above acceptable limits. Pool had been drained and was being refilled during inspection. Ensure water chemistry is balanced adequately daily. Maintain combined chlorine at the lowest level possible.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combine chlorine levels are above acceptable limits. Pool had been drained and was being refilled during inspection. Ensure water chemistry is balanced adequately daily. Maintain combined chlorine at the lowest level possible.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- Pool operators have not completed the pool safety certification as required. Enroll operators in the required pool training course.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?