BLVD Beltline - Swimming Pool
130 - 1229 Macleod Trail SE Calgary AB T2G 2N1 · Aquatic Facility
14 inspections
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample collected on July 6/26 had Total Coliforms present. - Treat the pool water and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on July 10/26 was not processed due to late submission. - Submit a resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample collected on July 6/26 had Total Coliforms present. - Treat the pool water and resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free available chlorine tested very low at 0.96 ppm and 0.33 ppm (2nd testing). - Maintain chlorine level above 1 ppm for adequate disinfection. Recommend keeping the chlorine level for the outdoor pool between 2.5-4.0 ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity tested low at 57 ppm. - Maintain total alkalinity between 60-180 gpm so the pH is kept balanced.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
6 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free available chlorine tested very low at 0.61 ppm. - Maintain the chlorine level above 1 ppm. Recommend to keep the chlorine level for the outdoor pool between 2.5-4.0 ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity tested low at 17 ppm. - Maintain total alkalinity between 60-180 gpm so the pH is kept balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Manual and automated pH readings were not consistent. - Calibrate the automated system.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- Some test reagents were expired. - Obtain new reagents for accurate testing.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- 1. There was a gap between the main drain cover and the pool wall. - No gaps are allowed between the wall and the covers as per the manufacturer's installation instructions.2. No visual checks of the main drains' condition are being conducted and results recorded. - The drain covers must be routinely inspected prior to opening each day and throughout the day.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Cyanuric Acid is not being tested at least weekly. - Test cyanuric acid regularly.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (25ES-158E00007) collected on June 6th, 2025, received on June 7th, 2025, was rejected by the lab as a non-urgent sample was received at the lab on a weekend. Please re-sample the swimming pool as soon as possible.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample taken May 12th, 2025 - HPC 670 CFU/mL.Please re-sample the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Sample taken Aug 16, 2024 - total coliforms present.-Treat and resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample taken Aug 16, 2024 - HPC 140 CFU/mL.-Resample
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A satisfactory water sample has not been received for this season.-Submit a new water sample for testing by Monday, July 8, 2024
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken Jun 4, 2024 - HPC 180 CFU/mL-Resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample take May 31, 2024 - HPC 1280 CFU/mL.-Resample
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity measured at 55 mg/L.-Maintain alkalinity between 60-180 mg/L
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample take May 31, 2024 - HPC 1280 CFU/mL.-Resample
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity measured at 55 mg/L.-Maintain alkalinity between 60-180 mg/L
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on September 20, 2023, had detected total coliforms in the sample.REQUIREMENT: Review the water chemistry and begin immediate treatment of the water. Review the water sampling technique to ensure that there wasn’t accidental contamination during the collection.Collect and send a re-sample immediately after you complete necessary treatments
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity measured at 55 mg/L.-Maintain alkalinity between 60-180 mg/L
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?