Bonnie Doon Leisure Centre - Whirlpool

8648 81 Street NW Edmonton AB T6C 2V9 · Aquatic Facility

Inspection summary

Bonnie Doon Leisure Centre - Whirlpool has been inspected 9 times by Alberta Health Services (Environmental Public Health) since October 20, 2023. The most recent inspection, on December 29, 2025, found no infractions.

4 of 9 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 5 separate inspections, most recently on December 16, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 15 Dec 2025 was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  3. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The float valves at the bottom of the skimmers were stuck down and restricting skimmer flow. Once the float valves were removed and adjusted skimming action was noted. Ensure staff check the float valves and ensure they are not blocking skimmer flow.
  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 27 Jan 2025 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 13 Aug 2024 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  8. Monitoring Inspection

    0 infractions

  9. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 17 Oct 2023 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. As the whirlpool has been closed for facility shut down since September 2023 no satisfactory sample has been received. The whirlpool must have a satisfactory sample before reopening.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 2 of the 4 skimmers did not have floating weirs installed to ensure proper skimming action. Install floating weirs or round weirs to ensure proper skimming action is occuring.