Skip to content
Loading map…

Days Inn Innisfail - Whirlpool

5010 40 Avenue Innisfail AB T4G 1Z1 · Aquatic Facility

Inspection summary

Days Inn Innisfail - Whirlpool has been inspected 11 times by Alberta Health Services (Environmental Public Health) since November 27, 2023. The most recent inspection, on May 23, 2025, recorded 1 infraction.

6 of 11 inspections on record found no infractions at all. No inspections are on record from the past 12 months. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times across 3 separate inspections, most recently on August 15, 2024. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on May 6, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 3 times across 2 separate inspections, most recently on May 23, 2025. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

11 inspections

  1. Risk Management Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The following water testing reagents were observed to be past their best before dates.-Thiosulphate CR 0007 (Feb 2025).-pH indicator CR 0004(Dec 2024)-Total Alkalinity CR-0008 (May 2025)**Please have these reagents replace to ensure accurate testing of water chemistry parameters.
  2. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free available chlorine = 1.85ppm.**Please adjust water chemistry to ensure FAC is maintained at above 2.0ppm.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily water chemistry testing records are not being adequately maintained. There were no dates/ time on the recent records observed in the file.**Please ensure adequate records are kept at all times.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The following water testing reagents were observed to be past their best before dates.-Thiosulphate CR 0007 (Feb 2025).-pH indicator CR 0004(Dec 2024)-Total Alkalinity CR-0008 (May 2025)**Please have these reagents replace to ensure accurate testing of water chemistry parameters.
  3. Monitoring Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free Available Chlorine: 1.13 ppmNote: Please adjust/add more chlorine to the whirlpool to meet the requirements of 2.0 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The rate of filtration is 15.3 GPM/sq ft. Note: The filtration rate does not meet the manufacturers (maximum 74 GPM with 15 GPM/sq ft.) and legislative requirements.Please adjust the flow rate 60 GPM to meet the requirements.
  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    0 infractions

  8. Demand Inspection

    0 infractions

  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated.The hot tub must be drained, cleaned, and disinfected and the filter cleaned and disinfected (or replaced). Refill the hot tub and bring disinfectant residuals back to normal levels.
  11. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated.The hot tub must be drained, cleaned, and disinfected and the filter cleaned and disinfected (or replaced). Refill the hot tub and bring disinfectant residuals back to normal levels.