Derma Medique Skin Therapy
596 Taralake Way NE Calgary AB T3J 0J1 · Personal Services
Inspection summary
Derma Medique Skin Therapy has been inspected once by Alberta Health Services (Environmental Public Health), on May 3, 2024. The most recent inspection, on May 3, 2024, recorded 4 infractions.
No inspections are on record from the past 12 months. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.
Equipment and utensilsLower risk
Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.
Recorded once on May 3, 2024. For example:
Is equipment that is intended to be sterile maintained sterile at the point of use?
Other findingsLower risk
Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.
Recorded 3 times on May 3, 2024. For example:
Are cosmetic products appropriate for their intended use and being handled properly?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
1 inspection
- Initial Inspection
4 infractions
- 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
- 1) A disposable catheter, used in some mesotherapy services, did not have any sterility assurance documentation on the package.REQUIREMENT: Do not use these disposable catheters. Ensure all critical equipment purchased as sterile has sterility assurance documentation.2) The operator's piercing gun contain components which must be cleaned and sterilized at the point of use. It doesn't appear that there is any method to disassemble, clean, and sterilize the gun.REQUIREMENT: Cease offering piercing services immediately. Obtain a piercing gun that has single-use, pre-sterilized cartridges at the piercing site.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Several types of protein threads used in the protein thread tightening service do not have a complete ingredients list in English/French. It appears that the protein is sourced from egg albumin. Additionally, it appears that some of the product (gold packaging) has expired, as the manufacturer's date indicated that it was manufactured in 2016 and expires after 3 years.REQUIREMENT: Do not offer protein thread tightening unless the protein threads have ingredients listed in French/English and use the protein threads in accordance with the manufacturer's instructions.
- 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
- 1) A plasma pen 'Maglev Maulwurf Sommerprosse' was identified at the premises. This brand/manufacturer does not appear to have a MDL from Health Canada, and has not been evaluated for safety, effectiveness or quality. REQUIREMENT: Do not use this plasma pen and discontinue the offering of this service unless a pen with a valid MDL from Health Canada can be obtained.2) The operator is providing electrocauterization services; this service has not been previously assessed.REQUIREMENT: Operator cannot provide electrocauterization services until the equipment and procedures are reviewed by a Public Health Inspector.
- 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
- MEBO Burn Ointment cream contains 0.25% beta-Sitosterol but does not have an NPN issued by Health Canada.REQUIREMENT: Use a burn ointment cream that has Health Canada approval (DIN or NPN).
- 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
Nearby inspected facilities
- VIP Group / Gogi Dhaliwal - Events
26 Taralake Cape NE Calgary AB T3J 0J1
2 inspections
- PSK Alberta Ltd. - Events
288 Taralake Landing NE Calgary AB T3J 0A6
2 inspections
- Eat-Well Cottage
16 Saddlestone Grove NE Calgary AB T3J 0Z6
1 inspection
- Shalimar Paan and Chatkhara House - Food
125 - 7171 80 Avenue NE Calgary AB T3J 0J2
4 inspections
- Crown Barbershop
314 - 7171 80 Avenue NE Calgary AB T3J 0N6
1 inspection
- Aatman Ayurveda and Massage - Food
408 - 7210 80 Avenue NE Calgary AB T3J 0N7
1 inspection
- Aatman Ayurveda and Massage
408 - 7210 80 Avenue NE Calgary AB T3J 0N7
3 inspections
- Wedding Henna Services
111 - 7210 80 Avenue NE Calgary AB T3J 0N7
2 inspections