Skip to content
Loading map…

Holiday Inn Express & Suites - Edmonton SW Windermere - Swimming Pool

6125 Andrews Loop SW Edmonton AB T6W 3G9 · Aquatic Facility

12 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 18.74 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 92 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less. (To achieve the proper rate of filtration, the flow rate should not exceed 73 gpm). Updated on June 16, 2026:* Rate of filtration for the filtration system was 19.35 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 95 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less. (To achieve the proper rate of filtration, the flow rate should not exceed 73 gpm). Updated on June 22, 2026:* Rate of filtration for the filtration system was 16.29 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 80 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less.
  3. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 18.74 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 92 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less. (To achieve the proper rate of filtration, the flow rate should not exceed 73 gpm). Updated on June 16, 2026:* Rate of filtration for the filtration system was 19.35 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 95 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less. (To achieve the proper rate of filtration, the flow rate should not exceed 73 gpm).
  4. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was 50 ppm. Ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 18.74 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 92 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less. (To achieve the proper rate of filtration, the flow rate should not exceed 73 gpm).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • One weir was missing in a skimmer. Please replace the missing weir.
  5. Risk Management Inspection

    0 infractions

  6. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration. Updated on February 11, 2025:Rate of filtration for the filtration system was 20.37 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate about 100 gpm. Ensure that the rate of filtration is 15 gpm/sq ft or less.
  7. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.75 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration.
  8. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 24EN-178E01134 submitted on June 26, 2024, was unsatisfactory: HPC 290.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.75 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration.
  9. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.75 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration.
  10. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample WE-23-0125681 submitted on November 22, 2023, was unsatisfactory: HPC 270.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.75 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration.
  11. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.75 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 19.3 gpm/sq ft (too fast) based on a filtration area of 4.91 sq ft. Ensure that the flow rate is around 73 gpm for required rate of filtration.
  12. Risk Management Inspection

    0 infractions