Skip to content
Loading map…

Holiday Inn Express & Suites - Edmonton SW Windermere - Whirlpool

6125 Andrews Loop SW Edmonton AB T6W 3G9 · Aquatic Facility

10 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 26EN-184E00204 submitted on July 3, 2026, was unsatisfactory: Total coliforms were present.
  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 1.87 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover period was 18.56 minutes, which is slower than required 15 minutes (volume 965 gal and flow rate about 52 gpm). To achieve the minimum required turnover period, the flow rate should be at least 64 gpm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. One weir was missing in a skimmer. Please replace the missing weir.2. Cleaning was required in the skimmers.
  5. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was 50 ppm. Ensure that the total alkalinity is maintained between 60 and 180 ppm.
  6. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was 50 ppm. Ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine residual was 2.28 ppm. Ensure that the combined chlorine is maintained at the lowest level possible (and below 1 ppm).
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on [Date] was unsatisfactory: HPC 490 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  9. Risk Management Inspection

    0 infractions

  10. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • One of the weirs was missing. Please install the missing weir.