Hotel Clique - North Hot Tub

24 Aero Crescent NE Calgary AB T2E 7Y5 · Aquatic Facility

18 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on May 5, 2026, was not tested because the water sample was received more than 24 hours after collection.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample that was collected on October 17, 2025, was not tested because the time of collection was not indicated. Another water sample must be submitted for testing.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on August 29, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced
  7. Risk Management Inspection

    0 infractions

  8. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On July 10th, 2025 the Free Chlorine Level was measured at 1.91 ppm.During the inspection operator adjustedFinal reading 3.82 ppm.Required: Ensure that FAC is always above 2.0ppm minium.
  9. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorines were measured to be 2.85 ppm on the Inspector's test kit. The operator, based on pool records, appears to be getting 1.0 ppm near daily.REQUIREMENT: Treat the combined chlorines so they're at the lowest level possible.
  10. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on June 19, 2025, was unsatisfactory with an HPC of 180 CFU/mL.**Please re-sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorines were measured to be 2.85 ppm on the Inspector's test kit. The operator, based on pool records, appears to be getting 1.0 ppm near daily.REQUIREMENT: Treat the combined chlorines so they're at the lowest level possible.
  11. Demand Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorines were measured to be 2.85 ppm on the Inspector's test kit. The operator, based on pool records, appears to be getting 1.0 ppm near daily.REQUIREMENT: Treat the combined chlorines so they're at the lowest level possible.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • February 27 weekly water sample could not be processed due to form error.UPDATE- March 3, 2025Sample collected and submitted February 28 (resample) was not processed.Sample collected February 28, 2025, late afternoon was submitted to Foothills Lab. Lab did not receive it until Saturday , March 1 at which time they would not process as it was a non-urgent sample submitted on weekend.
  12. Demand Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorines were measured to be 2.85 ppm on the Inspector's test kit. The operator, based on pool records, appears to be getting 1.0 ppm near daily.REQUIREMENT: Treat the combined chlorines so they're at the lowest level possible.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • February 27 weekly water sample could not be processed due to form error.
  13. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorines were measured to be 2.85 ppm on the Inspector's test kit. The operator, based on pool records, appears to be getting 1.0 ppm near daily.REQUIREMENT: Treat the combined chlorines so they're at the lowest level possible.
  14. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On April 29, 2024, the free chlorine level was measured at 1.49 ppm.On July 11, 2024, the free chlorine level was also measured at 1.49 ppm.REQUIREMENT: Maintain the FCL at a minimum or 2.0 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The water level is too high; the level is seen higher than the skimmer drain.REQUIREMENT: Maintain the water level at the same level as the skimmer.
  15. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on May 17, 2024, had Pseudomonas isolated in the sample.REQUIREMENT: Begin treatment for the whirlpool immediately. Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced. Indicate on the requisition form that the sample is a ‘resample’.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On April 29, 2024, the free chlorine level was measured at 1.49 ppm.REQUIREMENT: Maintain the FCL at a minimum or 2.0 ppm.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  16. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On April 29, 2024, the free chlorine level was measured at 1.49 ppm.REQUIREMENT: Maintain the FCL at a minimum or 2.0 ppm.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool water sample collected on 2023-11-24 showed that HPC was isolated at 110 CFU/mL.Requirement: Please treatment the hot tub in accordance with AHS unsatisfactory microbiological sample test results for public pools. and resample.
  18. Monitoring Inspection

    0 infractions