- Risk Management Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- **Outstanding Violation**The pH tested at the time of the inspection was 7.72.The pH of a swimming pool must not exceed a value of 7.6.The operator was directed to immediately decrease the whirlpool's pH to acceptable levels to rebalance the pool.The pool was to be rebalanced before allowing bathers to use the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- **Outstanding Violation**The North-East seat area of the whirlpool basin was observed to be chipping.The area of damage appears to be progressing to include sections of the stairs and seat area around the basin. Correction:- Repair the damaged section of the whirlpool basin
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Outstanding Violation**Written logs of the pool's chemical parameters are not being recorded daily by the operators.Free available chlorine, pH, and combined chlorines must be manually tested for and documented each day the pool is operating.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on December 3, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- **Outstanding Violation**The pH tested at the time of the inspection was 7.72.The pH of a swimming pool must not exceed a value of 7.6.The operator was directed to immediately decrease the whirlpool's pH to acceptable levels to rebalance the pool.The pool was to be rebalanced before allowing bathers to use the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- **Outstanding Violation**The North-East seat area of the whirlpool basin was observed to be chipping.The area of damage appears to be progressing to include sections of the stairs and seat area around the basin. Correction:- Repair the damaged section of the whirlpool basin
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Outstanding Violation**Written logs of the pool's chemical parameters are not being recorded daily by the operators.Free available chlorine, pH, and combined chlorines must be manually tested for and documented each day the pool is operating.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on November 12, 2025, had a Total Coliforms present in the sample. **Please begin treatment of the whirlpool immediately. **Submit a re-sample after treatment is complete and water chemistry is re-balanced.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- **Outstanding Violation**The pH tested at the time of the inspection was 7.72.The pH of a swimming pool must not exceed a value of 7.6.The operator was directed to immediately decrease the whirlpool's pH to acceptable levels to rebalance the pool.The pool was to be rebalanced before allowing bathers to use the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- **Outstanding Violation**The North-East seat area of the whirlpool basin was observed to be chipping.The area of damage appears to be progressing to include sections of the stairs and seat area around the basin. Correction:- Repair the damaged section of the whirlpool basin
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Outstanding Violation**Written logs of the pool's chemical parameters are not being recorded daily by the operators.Free available chlorine, pH, and combined chlorines must be manually tested for and documented each day the pool is operating.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH tested at the time of the inspection was 7.72.The pH of a swimming pool must not exceed a value of 7.6.The operator was directed to immediately decrease the whirlpool's pH to acceptable levels to rebalance the pool.The pool was to be rebalanced before allowing bathers to use the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Previously cited violation:The North-East seat area of the whirlpool basin was observed to be chipping.The area of damage appears to be progressing to include sections of the stairs and seat area around the basin. Correction:- Repair the damaged section of the whirlpool basin
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Written logs of the pool's chemical parameters are not being recorded daily by the operators.Free available chlorine, pH, and combined chlorines must be manually tested for and documented each day the pool is operating.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A satisfactory bacteriological water sample has not been confirmed for the pool since April 4, 2025. Bacteriological water samples must be submitted weekly.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH tested at the time of the inspection was 7.72.The pH of a swimming pool must not exceed a value of 7.6.The operator was directed to immediately decrease the whirlpool's pH to acceptable levels to rebalance the pool.The pool was to be rebalanced before allowing bathers to use the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Previously cited violation:The North-East seat area of the whirlpool basin was observed to be chipping.The area of damage appears to be progressing to include sections of the stairs and seat area around the basin. Correction:- Repair the damaged section of the whirlpool basin
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Written logs of the pool's chemical parameters are not being recorded daily by the operators.Free available chlorine, pH, and combined chlorines must be manually tested for and documented each day the pool is operating.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Previously cited violation:The North-East seat area of the whirlpool basin was observed to be chipping.Correction:- Repair the damaged section of the whirlpool basin
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Risk Management Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological results from the water sample collected on 22 January 2025 returned positive for pseudomonas aeruginosa.Correction:- Close whirlpool access to patrons- Implement the pseudomonas response protocol- Re-balance whirlpool parameters - Submit a re-sample prior to reopening
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Bacteriological results from the water sample collected on 22 January 2025 returned with an elevated HPC of 1570 CFU/mLCorrection:- Balance pool parameters- Reference the elevated HPC response protocol- Submit a resample
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Previously cited violation:The North-East seat area of the whirlpool basin was observed to be chipping.Correction:- Repair the damaged section of the whirlpool basin
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The North-East seat area of the whirlpool basin was observed to be chipping.Correction:- Repair the damaged section of the whirlpool basin
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Bacteriological Sample results from September 9, 2024 returned with Heterotrophic Plate Count (HPC) of 850 CFU / mL.Ensure that the pool's bacteriological parameters do not exceed the allowable maximum.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The North-East seat area of the whirlpool basin was observed to be chipping.Correction:- Repair the damaged section of the whirlpool basin
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The Free chlorine parameters were measured to be in excess of measuring equipment (12 ppm+) without notification to patrons.- No patrons were present at the time of inspectionCorrected during inspection:- Notification of parameter adjustment was placed by the whirlpool area
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The North-East seat area of the whirlpool basin was observed to be chipping.Correction:- Repair the damaged section of the whirlpool basin
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseudomonas detected in routine sample received 31 August 2023.- Operator contacted and the whirlpool was closedCorrection:- Follow pseudomonas pool protocol, maintain pool parameters- Submit a satisfactory bacteriological re-sample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Bacteriological Water Samples received 31 August 2023 returned with HPC in excess of 57000Correction:- Clean, Scrub, and hyper chlorinate system- Submit a satisfactory bacteriological re-sample
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Sample results from the Provincial Laboratory confirmed the presence of Total Coliform bacteria per 100 mL of the wading pool water sample submitted on August 2, 2023.Ensure that the pool's bacteriological water quality is compliant, and that Total Coliform Bacteria are not detected. A re-sample was submitted August 9, 2023 after the pool had been treated.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Sample results from the Provincial Laboratory confirmed the isolation of Pseudomonas aeruginosa bacteria per 100 mL of the wading pool water sample submitted on August 2, 2023.Ensure that the pool's bacteriological water quality is compliant, and that Pseudomonas aeruginosa is not isolated. A re-sample was submitted August 9, 2023 after the pool had been treated.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample results from the Provincial Laboratory indicated a Heterotrophic Plate Count (HPC) greater than 57000 CFU / mL in the wading pool water sample submitted on July 31, 2023.Ensure that the pool's bacteriological water quality is compliant, and that HPC is less than or equal to 100 CFU / mL.A re-sample was submitted August 9, 2023 after the pool had been treated.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions