Pocaterra Inn and Waterslide - Swimming Pool

1725 Bow Valley Trail Canmore AB T1W 2W1 · Aquatic Facility

Inspection summary

Pocaterra Inn and Waterslide - Swimming Pool has been inspected 20 times by Alberta Health Services (Environmental Public Health) since January 30, 2024. The most recent inspection, on August 31, 2026, found no infractions.

5 of 20 inspections on record found no infractions at all. In the past 12 months there were 7 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 21 times across 15 separate inspections, most recently on August 23, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 10 times across 8 separate inspections, most recently on November 26, 2024. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 4 times across 4 separate inspections, most recently on July 26, 2024. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times across 2 separate inspections, most recently on November 26, 2024. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

20 inspections

  1. Demand Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday August 17th, 2026, had an HPC of 370 CFU/ml. - Operators were informed to treat and re-sample.
  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday August 17th, 2026, had an HPC of 370 CFU/ml. - Operators were informed to treat and re-sample.
  4. Demand Inspection

    0 infractions

  5. Demand Inspection

    0 infractions

  6. Monitoring Inspection

    0 infractions

  7. Demand Inspection

    0 infractions

  8. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • *Outstanding Violation*There was a leak coming from the pool filter. - Please repair the leak, ensure the circulation system is in good repair.
  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday March 24th, 2025, had a HPC of 1,020 CFU/ml. - Operators were informed to treat and re-sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a leak coming from the pool filter. - Please repair the leak, ensure the circulation system is in good repair.
  10. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday March 3rd, 2025, had a HPC of 240 CFU/ml. - Operators were informed to treat and re-sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a leak coming from the pool filter. - Please repair the leak, ensure the circulation system is in good repair.
  11. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a leak coming from the pool filter. - Please repair the leak, ensure the circulation system is in good repair.
  12. Demand Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a leak coming from the pool filter. - Please repair the leak, ensure the circulation system is in good repair.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Repeat Violation**The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
  13. Risk Management Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 27 ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was measured as 2ppm and there was a strong "chloramine" smell in the pool area. Combined chlorine level in the pool water to be reduced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • *Please ensure combined chlorine levels are tested daily*Does not appear the combined chlorine level is being tested. In the pool logs (approximately 3 weeks of entries were present) the combined chlorine was written as 0ppm every time and when tested today using the pool operator's testing kit, measured as 1ppm. Combined chlorine level is to be tested daily.
  14. Demand Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 27 ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was measured as 2ppm and there was a strong "chloramine" smell in the pool area. Combined chlorine level in the pool water to be reduced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Does not appear the combined chlorine level is being tested. In the pool logs (approximately 3 weeks of entries were present) the combined chlorine was written as 0ppm every time and when tested today using the pool operator's testing kit, measured as 1ppm. Combined chlorine level is to be tested daily.
  15. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • October 28, 2024 water sample had a plate count of 270cfu/ml. Treat water to remove contamination. Resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 33 ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
  16. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 33 ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
  17. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample received 7/26/2024 was not processed by the lab, date on the form indicated it was received more than 24 hrs. after collection. Operators were informed to submit a re-sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 41ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow rate could not be determined for the waterslide pump as the float was stuck in the flow meter. Please repair the flow meter for the waterslide pump.
  18. Demand Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 41ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow rate could not be determined for the waterslide pump as the float was stuck in the flow meter. Please repair the flow meter for the waterslide pump.
  19. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday June 3rd, 2024, had an HPC of 390 cfu/ml. - Operators were informed to treat and re-sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 41ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow rate could not be determined for the waterslide pump as the float was stuck in the flow meter. Please repair the flow meter for the waterslide pump.
  20. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was low, 41ppm. - Raise the alkalinity, ensure it is maintained in the 60-180 ppm range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The skimmers are missing floating weirs. - Ensure all skimmers have floating weirs to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow rate could not be determined for the waterslide pump as the float was stuck in the flow meter. Please repair the flow meter for the waterslide pump.