Skip to content
Loading map…

Pomeroy Inn & Suites - Swimming Pool

4111 51 Street Vermilion AB T9X 0B4 · Aquatic Facility

Inspection summary

Pomeroy Inn & Suites - Swimming Pool has been inspected 13 times by Alberta Health Services (Environmental Public Health) since October 30, 2023. The most recent inspection, on March 24, 2026, found no infractions.

6 of 13 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 6 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 6 times across 6 separate inspections, most recently on November 18, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 4 times across 4 separate inspections, most recently on November 18, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

13 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • - Premise has had a recent sample with total coliforms present but no HPC (sample from November 12th positive for coliforms).- Discussed results with operator, will require further follow-up sampling.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH = 7.8 to 8.0 above required pool standards- Request that operator adjust treatment system for proper pool pH balance.- Free Chlorine = 3.49 mg/L- Combined Chlorine = 0.42 mg/L
  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • - Premise has had a recent sample with total coliforms present but no HPC (sample from November 12th positive for coliforms).- Discussed results with operator, will require further follow-up sampling.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH = 7.8 to 8.0 above required pool standards- Request that operator adjust treatment system for proper pool pH balance.
  4. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • - Premise has had a recent sample with total coliforms present but no HPC.- Discussed results with operator, showed sample results. Will require further follow-up sampling.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH = 7.7 to 7.8 above required pool standards- Request that operator adjust treatment system for proper pool pH balance.- Free Chlorine = 0.95 to 1.0 mg/L- Total Chlorine = verified (3 tests) highest result 1.7 mg/L- Combined Chlorine up to 0.69 mg/L
  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Note: tested for pH only at this time.pH= 7.9 to 8.0 mg/L (still HIGH)- Discussed concern pertaining to high pH reading with site manager at this time, Directed them to treat pool, reduce pH to acceptable level.
  7. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • - Free Cl = 4.23 mg/L- Combined Cl = 0.34 mg/L- pH = 8.1 mg/L (HIGH)- Discussed concern pertaining to high pH reading with site manager present at this time, Directed them to treat pool, reduce pH to acceptable level.
  8. Monitoring Inspection

    0 infractions

  9. Risk Management Inspection

    0 infractions

  10. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH = 7.7 to 7.8 elevatedChlorine Free = 7.0 mg/LCombined Chlorine = 0.5 mg/L- Request that operators look at adjusting the chlorine residual and pH, recommend reviewing the saturation index for this water body.
  11. Demand Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 150 is over the maximum acceptable limit of 100 - as per section 6.1(a) of the Alberta Health Pool Standards. Ideally, the HPC levels should be less than 10.No immediate action required now but continue to submit weekly water samples and monitor future levels of HPC.
  13. Monitoring Inspection

    0 infractions

Nearby inspected facilities

Own this business? Add a badge to your website