Pomeroy Inn & Suites - Whirlpool

4111 51 Street Vermilion AB T9X 0B4 · Aquatic Facility

Inspection summary

Pomeroy Inn & Suites - Whirlpool has been inspected 13 times by Alberta Health Services (Environmental Public Health) since October 30, 2023. The most recent inspection, on March 24, 2026, found no infractions.

8 of 13 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 1 infraction recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

The last 3 inspections in a row found no infractions. The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 4 times across 4 separate inspections, most recently on July 10, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times across 2 separate inspections, most recently on October 24, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

13 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • - Total coliforms present in most recent sample submitted.- Discussed with operator unsatisfactory result.- Will require further follow up and sampling.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected on July 08, 2025: Total coliforms PRESENTPseudomonas aeruginosa ISOLATEDOperator stated that the pool was down since July 08 due to malfunctioning equipment. The parts will be replaced, and the pool will be drained, refilled, and treated, followed by resampling. PHI emailed treatment procedure to the operator.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC >57,000 CFU/mL
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - ORP = 713mV- Alkalinity at time of review (utilizing both digital and manual (Taylor) testing equipment) = ~25 mg/L, Below required operating requirements -- Requested operators have the Alkalinity adjusted to proper operating range a set out by Pool regulations and Standards.
  7. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - ORP = 713mV- Alkalinity at time of review (utilizing both digital and manual (Taylor) testing equipment) = ~25 mg/L, Below required operating requirements -- Requested operators have the Alkalinity adjusted to proper operating range a set out by Pool regulations and Standards.
  8. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - ORP = 713mV- Alkalinity at time of review (utilizing both digital and manual (Taylor) testing equipment) = ~25 mg/L, Below required operating requirements -- Requested operators have the Alkalinity adjusted to proper operating range a set out by Pool regulations and Standards.
  9. Monitoring Inspection

    0 infractions

  10. Risk Management Inspection

    0 infractions

  11. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - Alkalinity = LOW, to low to read.- ORP = 711 mV- Request that operators adjust water body treatment and maintain Alkalinity between 80 to 120 mg/L.
  12. Demand Inspection

    0 infractions

  13. Monitoring Inspection

    0 infractions