Skip to content
Loading map…

Quality Inn & Suites Rimbey - Whirlpool

5501 50 Avenue Rimbey AB T0C 2J0 · Aquatic Facility

Inspection summary

Quality Inn & Suites Rimbey - Whirlpool has been inspected 7 times by Alberta Health Services (Environmental Public Health) since June 16, 2025. The most recent inspection, on July 22, 2026, found no infractions.

3 of 7 inspections on record found no infractions at all. In the past 12 months there were 6 inspections with 10 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The last 2 inspections in a row found no infractions. The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 4 separate inspections, most recently on March 27, 2026. For example: Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 4 times across 4 separate inspections, most recently on March 27, 2026. For example: Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Risk Management Inspection

    2 infractions

    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • - The up to date pool permit has not been posted. Please ensure the up to date pool permit is posted in a conspicuous place for patron to easily view.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Current: The emergency phone is not in good working order. There appears to be a faulty/loose connection. PHI had to physically adjust the phone base in order to achieve a connection. Previous: The emergency phone is not in good working order. When tested, there is no dial tone, and the front desk clerk was not able to be reached. Please ensure the phone is repaired to ensure reliable access to the front desk in the event of an emergency.
  4. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The submitted bacteriological water sample submitted on February 24, 2026, had Pseudomonas aeruginosa isolated by the Provincial Laboratory.Ensure that the pool water is treated as deemed necessary by the pool operator and that a re-sample is submitted for the pool ASAP.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The submitted bacteriological water sample submitted on February 24, 2026, had a Heterotrophic Plate Count level of 450 CFU/mL confirmed by the Provincial Laboratory.The operator confirmed that the chemical parameters were satisfactory leading up to and following the sample collection. Ensure that the pool water is treated as deemed necessary by the pool operator and that a re-sample is submitted for the pool ASAP.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • - The up to date pool permit has not been posted. Please ensure the up to date pool permit is posted in a conspicuous place for patron to easily view.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Current: The emergency phone is not in good working order. There appears to be a faulty/loose connection. PHI had to physically adjust the phone base in order to achieve a connection. Previous: The emergency phone is not in good working order. When tested, there is no dial tone, and the front desk clerk was not able to be reached. Please ensure the phone is repaired to ensure reliable access to the front desk in the event of an emergency.
  5. Risk Management Inspection

    2 infractions

    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • - The up to date pool permit has not been posted. Please ensure the up to date pool permit is posted in a conspicuous place for patron to easily view.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Current: The emergency phone is not in good working order. There appears to be a faulty/loose connection. PHI had to physically adjust the phone base in order to achieve a connection. Previous: The emergency phone is not in good working order. When tested, there is no dial tone, and the front desk clerk was not able to be reached. Please ensure the phone is repaired to ensure reliable access to the front desk in the event of an emergency.
  6. Monitoring Inspection

    2 infractions

    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • - The up to date pool permit has not been posted. Please ensure the up to date pool permit is posted in a conspicuous place for patron to easily view.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • - The emergency phone is not in good working order. When tested, there is no dial tone, and the front desk clerk was not able to be reached. Please ensure the phone is repaired to ensure reliable access to the front desk in the event of an emergency.