Skin Lueur Aesthetics and Laser Centre (South) Inc.
5924 104 Street NW Edmonton AB T6H 2K3 · Personal Services
7 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- The concentration of the high-level disinfectant was tested, but the test strips were improper. Please obtain new test strips.
- 20. Is reusable equipment disinfected properly?
- Risk Management Inspection
3 infractions
- 20. Is reusable equipment disinfected properly?
- The concentration of the high-level disinfectant was tested, but the test strips were improper. Please obtain new test strips.
- 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
- Needles used for wart removal were used against manufacturer's instructions (labelled as "acupuncture" needles) and did not have adequate sterility assurance information available (no lot number). Please discontinue use of these needles and obtain appropriate needles.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- The M-369 machine (energy-emmitting device) did not have a manufacturer's manual. If manual is not available, discontinue use of the equipment.
- 20. Is reusable equipment disinfected properly?
- Monitoring Inspection
6 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Written procedures for skin cleansing and antiseptic use prior to services were not available.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Sterility assurance documentation for needles and microneedles was not kept with clients' forms. Ensure that sterility assurance documentation is kept with clients' forms for at least 2 years.
- 20. Is reusable equipment disinfected properly?
- The concentration of the high-level disinfectant was tested, but the test strips were improper. Please obtain new test strips.
- 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
- Needles used for wart removal were used against manufacturer's instructions (labelled as "acupuncture" needles) and did not have adequate sterility assurance information available (no lot number). Please discontinue use of these needles and obtain appropriate needles.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- The M-369 machine (energy-emmitting device) did not have a manufacturer's manual. If manual is not available, discontinue use of the equipment.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- The numbing cream used for microneedling service and Ultrasound Gel were used against manufacturer's instructions (expired). Please obtain new products.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Monitoring Inspection
5 infractions
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
- A reusable towel was observed at a hand sink. Ensure that a single-use towel or paper towel is used. Addressed during the inspection.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Sterility assurance documentation for needles and microneedles was not kept with clients' forms. Ensure that sterility assurance documentation is kept with clients' forms for at least 2 years. Discussed.
- 20. Is reusable equipment disinfected properly?
- High-level disinfectant (Preempt CS20) expired on September 21, 2021.
- 20. Is reusable equipment disinfected properly?
- The concentration of the high-level disinfectant was not tested, and no test strips were available.
- 20. Is reusable equipment disinfected properly?
- No records of testing the high-level disinfectant were available.
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?