Stony Plain Travelodge - Whirlpool

74 Boulder Boulevard Stony Plain AB T7Z 1V7 · Aquatic Facility

Inspection summary

Stony Plain Travelodge - Whirlpool has been inspected 17 times by Alberta Health Services (Environmental Public Health) since November 16, 2023. The most recent inspection, on May 29, 2026, recorded 1 infraction.

None of the 17 inspections on record were free of infractions. In the past 12 months there were 9 inspections with 30 infractions recorded. The higher-risk findings here relate to: Food temperature control, Chemicals and toxic substances and Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 15 times across 9 separate inspections, most recently on May 29, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 15 times across 14 separate inspections, most recently on February 13, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 13 times across 10 separate inspections, most recently on May 22, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 4 times across 3 separate inspections, most recently on January 22, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

17 inspections

  1. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  2. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa bacteria were present in the water sample submitted this week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 19, 2026, water sample showed the HPC count measured at 220 CFU/mL
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  3. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  4. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was around 3.26ppm. The spa tech operator added oxidizer and said to re-check the chlorine levels in a few hours.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The chlorine levels in the hot tub were too high. PHI tried testing the chlorine levels with their pool kit and 1st reading was "over range", then the dilution test read "over range". PHI used a chlorine test strip, and the strip indicated chlorine levels were higher than 50ppm (dark purple color).Due to this value PHI did not re-open the hot tub. PHI asked that general manager email PHI tomorrow with the chlorine values and if they are within regulatory range, PHI will permit re-opening the hot tub.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  5. Demand Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was around 3.26ppm. The spa tech operator added oxidizer and said to re-check the chlorine levels in a few hours.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  6. Risk Management Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine level was measured at 0.43ppm, when re-measured it was at 0.31 This is not sufficient disinfection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The sand filter for the hot tub is leaking. PHI observed the sand filter sitting in a pool of water. Ensure the sand filter is functioning properly.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  7. Demand Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine level was measured at 0.62ppm. This is not sufficient disinfection.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
  8. Demand Inspection

    8 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH of hot tub was measured at 8.21. This value is too high and must be within regulatory requirements.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The total chlorine levels were too high for PHI's pool test kit to read (reading came back as "Over Range"). A dilution test had to be performed to get a reading. Second reading was >10ppm. Although there is no upper range of chlorine levels in Alberta's legislation it is recommended to have chlorine between 2-5ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Several plumbing fixtures/pipes and filters had crystallization and mineral deposits build up.Required Action: Repair or replace leaking plumbing and filter. Clean up crystalized mineral build up.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Towels of different sizes found on several plumbing fixtures and filters, secured by pegs to soak up leakage was observed during the inspection. Required Action: Remove towels from filter and plumbing fixtures and repair or replace damaged equipment.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like. Water is leaking near an electrical outlet near the hot tub filter. Walls within the mechanical room are damaged and require repair.Required Action: Repair or replace damage outlets and walls.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Inadequate labelling of features to distinguish between whirlpool and the swimming pool equipment (sand filter etc.)
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Expired water quality testing chemical reagents were observed.Required Action: Discard all expired chemical reagents. Please ensure that all components of the water quality testing kit are maintained in good working condition and labeled with correct expiration dates
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • PHI did not observe manual tests written in the binder where the pool operator typically records pool chemistry tests. Ensure hot tub and pool are being manually monitored. Free chlorine, combined chlorine and PH must be tested at least once per day, automated readings and associated set points must be recorded once per day. Total alkalinity must be tested and recorded at least once per week.
  9. Demand Inspection

    7 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 40 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.UPDATE: November 28, 2025The Total Alkalinity of the hot tub was measured to be at 51 ppm.Required Action: Increase Total Alkalinity to a range of 60ppm - 180ppm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The total chlorine levels were too high for PHI's pool test kit to read (reading came back as "Over Range"). Ensure the chlorine levels are within regulatory range of 2ppm or above but not too high the total chlorine cannot be tested.Update: November 28, 2025Free chlorine reading over range. High chlorine levels are harmful to bathers as it irritates the skin, eyes, and respiratory system, and can cause chemical burns or long-term health effects if exposure is frequent.Required Action: Please ensure the chlorine levels are at a minimum of 2ppm but not greater than 5ppm so chlorine levels can be tested.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Several plumbing fixtures/pipes and filters had crystallization and mineral deposits build up.Required Action: Repair or replace leaking plumbing and filter.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Towels of different sizes found on several plumbing fixtures and filters, secured by pegs to soak up leakage was observed during the inspection. Required Action: Remove towels from filter and plumbing fixtures and repair or replace damaged equipment.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Electrical outlets were rusted and the walls around the outlet was dark gray and fuzzy, seems burnt or mold-like.Required Action: Repair or replace damage outlets and wall.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Inadequate labelling of features to distinguish between whirlpool and the swimming pool equipment (sand filter, manual records, flowmeter, and automated controller)Required Action: Please ensure proper labelling of features and manual record.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • -Expired water quality testing chemical reagents were observed.Required Action: Discard all expired chemical reagents. Please ensure that all components of the water quality testing kit are maintained in good working condition.
  10. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 40 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The total chlorine levels were too high for PHI's pool test kit to read (reading came back as "Over Range"). Ensure the chlorine levels are within regulatory range of 2ppm or above but not too high the total chlorine cannot be tested.
  11. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The heterotrophic plate count from the bacteriological water sample on September 9, 2025, was elevated at 190 CFU/100mL.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 40 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The total chlorine levels were too high for PHI's pool test kit to read (reading came back as "Over Range"). Ensure the chlorine levels are within regulatory range of 2ppm or above but not too high the total chlorine cannot be tested.
  12. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 40 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The total chlorine levels were too high for PHI's pool test kit to read (reading came back as "Over Range"). Ensure the chlorine levels are within regulatory range of 2ppm or above but not too high the total chlorine cannot be tested.
  13. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The free available chlorine levels in the hot tub were between 0.83-1.07ppm. This is too low. Hot tubs must have a free available chlorine level of 2ppm or can operate lower if the ORP is 700mV. ORP levels were measured at 634mV at time of inspection.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 32 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
  14. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 33 ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover rate for the hot tub was calculated at 22mins. This is too long. Turnover rate must be 15 minutes or less.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The chlorine levels in the hot tub could not be measured with the Pool Digital test kit at time of inspection. Reading was "over range". Chlorine levels could not be read at time of inspection. Recommended to keep chlorine levels around 3-5ppm
  15. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 17ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter did not appear to be working properly. Ensure the flow meter is reading flow rate.
  16. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 23ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm. Nov 24, 2023: Total Alkalinity was still low, measured to be at 35ppm.
  17. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity of the hot tub was measured to be at 23ppm.Please note that that Total Alkalinity must be maintained between 60ppm - 180ppm.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The observed testing and monitoring records for the hot tub does not contain Combined Chlorine and Total Alkalinity readings. Please ensure Combined Chlorine is tested and recorded at least once a day while the Total Alkalinity is measured and recorded at least once per week.