Skip to content
Loading map…

Super 8 by Wyndham Cochrane - Hot Tub

11 West Side Drive Cochrane AB T4C 1M1 · Aquatic Facility

Inspection summary

Super 8 by Wyndham Cochrane - Hot Tub has been inspected 4 times by Alberta Health Services (Environmental Public Health) since October 30, 2023. The most recent inspection, on October 14, 2026, recorded 9 infractions.

None of the 4 inspections on record were free of infractions. In the past 12 months there were 2 inspections with 17 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Food temperature control and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 14 times across 4 separate inspections, most recently on October 14, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 7 times across 4 separate inspections, most recently on October 14, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on October 30, 2023. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 3 times across 3 separate inspections, most recently on October 14, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 3 times across 3 separate inspections, most recently on October 14, 2026. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

4 inspections

  1. Demand Inspection

    9 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from May 25 was not processed by the lab due to wrong (due to wrong date lab stated that sample was received more than 24hrs. after collection) information on the requisition form.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on Oct. 13 was not processed by the lab due to no identification number on the bottle.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter was not functional during the inspection. Please make sure required repairs are completed.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine level is the whirlpool was 10ppm. Chlorine level to be reduced but still maintained at a minimum of 2ppm.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Suction outlet cover date is expired. Please make sure proper outlet cover meets with new SOFA (Suction Outlet Fitting Assemblies) requirements.Please provide the copy of information sheet for Suction outlet cover (the sheet that gives installation instructions should have model and date too)
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the inlet covers were missing.Surface on one of the jets was rusted, not in a good repair. ***Please make sure required repairs are completed.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was crack tile beside the main drain cover. Sharp cornersJet covers were missing 2 upper and 2 bottom jet covers and had sharp corners.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • *Testing kit was not capable of measuring FC over 5ppm. There were multiple times FC was 0ppm and 10ppm and there was no information what has been done if the FC was 0 , and test kit was capable of measuring over 5ppm/*Clarity of the pool is not being checked and recorded on the pool logs. To be checked daily and added to the pool log.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Suction Outlet cover was expired in 2021. Anti-entrapment plan needs to be updated after the new outlet cover installation.*Temperature requirement for whirlpool, steam room needs to be written on the signage .*Location of the fire alarm, telephone or other emergency devices, where applicable Signage is required to be updated.
  2. Demand Inspection

    8 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from May 25 was not processed by the lab due to wrong (due to wrong date lab stated that sample was received more than 24hrs. after collection) information on the requisition form.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter was not functional during the inspection. Please make sure required repairs are completed.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine level is the whirlpool was 10ppm. Chlorine level to be reduced but still maintained at a minimum of 2ppm.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Suction outlet cover date is expired. Please make sure proper outlet cover meets with new SOFA (Suction Outlet Fitting Assemblies) requirements.Please provide the copy of information sheet for Suction outlet cover (the sheet that gives installation instructions should have model and date too)
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the inlet covers were missing.Surface on one of the jets was rusted, not in a good repair. ***Please make sure required repairs are completed.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was crack tile beside the main drain cover. Sharp cornersJet covers were missing 2 upper and 2 bottom jet covers and had sharp corners.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • *Testing kit was not capable of measuring FC over 5ppm. There were multiple times FC was 0ppm and 10ppm and there was no information what has been done if the FC was 0 , and test kit was capable of measuring over 5ppm/*Clarity of the pool is not being checked and recorded on the pool logs. To be checked daily and added to the pool log.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Suction Outlet cover was expired in 2021. Anti-entrapment plan needs to be updated after the new outlet cover installation.*Temperature requirement for whirlpool, steam room needs to be written on the signage .*Location of the fire alarm, telephone or other emergency devices, where applicable Signage is required to be updated.
  3. Monitoring Inspection

    7 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter was not functional during the inspection. Please make sure required repairs are completed.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine level is the whirlpool was 10ppm. Chlorine level to be reduced but still maintained at a minimum of 2ppm.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Suction outlet cover date is expired. Please make sure proper outlet cover meets with new SOFA (Suction Outlet Fitting Assemblies) requirements.Please provide the copy of information sheet for Suction outlet cover (the sheet that gives installation instructions should have model and date too)
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the inlet covers were missing.Surface on one of the jets was rusted, not in a good repair. ***Please make sure required repairs are completed.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was crack tile beside the main drain cover. Sharp cornersJet covers were missing 2 upper and 2 bottom jet covers and had sharp corners.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • *Testing kit was not capable of measuring FC over 5ppm. There were multiple times FC was 0ppm and 10ppm and there was no information what has been done if the FC was 0 , and test kit was capable of measuring over 5ppm/*Clarity of the pool is not being checked and recorded on the pool logs. To be checked daily and added to the pool log.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Suction Outlet cover was expired in 2021. Anti-entrapment plan needs to be updated after the new outlet cover installation.*Temperature requirement for whirlpool, steam room needs to be written on the signage .*Location of the fire alarm, telephone or other emergency devices, where applicable Signage is required to be updated.
  4. Monitoring Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Water result from February 22 bacteriological sample came back present for pseudomonas and 690CFU/mL.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity measured 38 ppm.Adjust the alkalinity so that it remains within the required range.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Suction outlet cover date is expired. Please make sure proper outlet cover meets with new SOFA (Suction Outlet Fitting Assemblies) requirements.Please provide the copy of information sheet for Suction outlet cover (the sheet that gives installation instructions should have model and date too)
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the jet covers were missing.Surface on one of the jets was rusted, not in a good repair. There was a pipe leaking at the sand filter. ***Please make sure required repairs are completed.

Nearby inspected facilities