Timberline Lodges - Swimming Pool
101 Stewart Creek Landing Canmore AB · Aquatic Facility
11 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- No water sample was submitted the week of May 25/26. A water sample is required to be submitted each week.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on June 5/26 was not tested as it was received at the lab after it had closed for the weekend. New water sample is to be submitted as soon as possible this week.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The free chlorine was initially measured as 0.73ppm but was 1.21ppm by end of the inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- One skimmer did not appear to have much flow through it; corrected during inspection.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Thursday September 25th, 2025, had an HPC of 140 CFU/ml. - Operators were informed to treat and re-sample.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Thursday May 1st, 2025, had an HPC of 110 CFU/ml. - Operators were informed to treat and re-sample.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- March 24/25 water sample was not tested as it arrived at the lab frozen. Resample to be submitted his week.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- December 27, 2024 water sample was not tested. Resample to be submitted.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- April 11/24 water sample had a plate count of 200 cfu/ml. Treat water to remove contamination and resample.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Steps were all removed, holes will be filled in and steps replaced with a pool ladder.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Monitoring Inspection
2 infractions
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One of the steps on side of pool is broken. To be repaired/replaced. Please ensure until this is done that there are no sharp edges that could injure someone.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water samples were not submitted for the swimming pool the weeks of July 3 or July 10, 2023. Samples are to be submitted for bacteriological testing every 7 days.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The maximum flow through the drain covers is exceeded when both the circulation pump and water feature pump are on. New drain covers that can handle the flow of both pumps are on order; in the meantime, flow to the water features pump has been shut off (and handle for valve removed) and pump shut off to prevent its use until new drain covers are installed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?