565 Griesbach Parade NW - Swimming Pool
565 Griesbach Parade NW Edmonton AB T5E 1Y8 · Aquatic Facility
Inspection summary
565 Griesbach Parade NW - Swimming Pool has been inspected 19 times by Alberta Health Services (Environmental Public Health) since May 30, 2024. The most recent inspection, on September 28, 2026, recorded 4 infractions.
6 of 19 inspections on record found no infractions at all. In the past 12 months there were 9 inspections with 20 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Food temperature control.
Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 16 times across 11 separate inspections, most recently on September 28, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 5 times across 5 separate inspections, most recently on September 28, 2026. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
Permits, records and postingLower risk
Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.
Recorded 4 times across 4 separate inspections, most recently on September 28, 2026. For example:
Are proper testing, monitoring, and other records being properly maintained?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
19 inspections
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 24/09/2026 [ID#: 26-EN-267E00648] was unsatisfactory: HPC 160 CFU/mL. This was the third consecutive unsatisfactory sample received. Pool was closed for the season. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 17/09/2026 [ID#: 26-EN-250E00704] was unsatisfactory: HPC 220 CFU/mL. This was a consecutive unsatisfactory sample result received. Requested that the outdoor pool be closed until a satisfactory microbiological sample result is received. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Sections of tiles were missing in the pool basin in various locations.2. Concerns with improper grouting in various locations - tile spacers between individual tiles were visible.3. There were two pool ladders in the deep end of the pool. One of the pool ladders was missing treads. Operator agreed to install caution tape around the ladder with missing treads until repairs are done.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. According to the daily logs, free chlorine is documented as "OR - over range" without additional action taken by staff. Ensure the pool test kit has been properly validated. Ensure staff are properly trained on how to use the pool test kit. Chlorine levels higher than the test kit range (i.e., over-range samples) can be measured using dilution. True high free chlorine range can cause interference with other chemical parameters. 2. Proper operator records were not being documented daily including but not limited to: day/month/year, staff responsible, time of tests etc. Discussed improvements required. Request that chemical parameters and automated controller readings be tested/documented twice daily (a.m. & p.m.) or more often as deemed necessary. If chemical parameters are not within legislative requirements, ensure the basin is closed to the public until corrective actions have been taken and chemical parameters are within legislative requirements.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 17/09/2026 [ID#: 26-EN-250E00704] was unsatisfactory: HPC 220 CFU/mL. This was a consecutive unsatisfactory sample result received. Requested that the outdoor pool be closed until a satisfactory microbiological sample result is received. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Sections of tiles were missing in the pool basin in various locations.2. Concerns with improper grouting in various locations - tile spacers between individual tiles were visible.3. There were two pool ladders in the deep end of the pool. One of the pool ladders was missing treads. Operator agreed to install caution tape around the ladder with missing treads until repairs are done.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. According to the daily logs, free chlorine is documented as "OR - over range" without additional action taken by staff. Ensure the pool test kit has been properly validated. Ensure staff are properly trained on how to use the pool test kit. Chlorine levels higher than the test kit range (i.e., over-range samples) can be measured using dilution. True high free chlorine range can cause interference with other chemical parameters. 2. Proper operator records were not being documented daily including but not limited to: day/month/year, staff responsible, time of tests etc. Discussed improvements required. Request that chemical parameters and automated controller readings be tested/documented twice daily (a.m. & p.m.) or more often as deemed necessary. If chemical parameters are not within legislative requirements, ensure the basin is closed to the public until corrective actions have been taken and chemical parameters are within legislative requirements.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on 10/09/2026 [ID#: 26-EN-253E00763] was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Sections of tiles were missing in the pool basin in various locations.2. Concerns with improper grouting in various locations - tile spacers between individual tiles were visible.3. There were two pool ladders in the deep end of the pool. One of the pool ladders was missing treads. Operator agreed to install caution tape around the ladder with missing treads until repairs are done.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. According to the daily logs, free chlorine is documented as "OR - over range" without additional action taken by staff. Ensure the pool test kit has been properly validated. Ensure staff are properly trained on how to use the pool test kit. Chlorine levels higher than the test kit range (i.e., over-range samples) can be measured using dilution. True high free chlorine range can cause interference with other chemical parameters. 2. Proper operator records were not being documented daily including but not limited to: day/month/year, staff responsible, time of tests etc. Discussed improvements required. Request that chemical parameters and automated controller readings be tested/documented twice daily (a.m. & p.m.) or more often as deemed necessary. If chemical parameters are not within legislative requirements, ensure the basin is closed to the public until corrective actions have been taken and chemical parameters are within legislative requirements.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Sections of tiles were missing in the pool basin in various locations.2. Concerns with improper grouting in various locations - tile spacers between individual tiles were visible.3. There were two pool ladders in the deep end of the pool. One of the pool ladders was missing treads. Operator agreed to install caution tape around the ladder with missing treads until repairs are done.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. According to the daily logs, free chlorine is documented as "OR - over range" without additional action taken by staff. Ensure the pool test kit has been properly validated. Ensure staff are properly trained on how to use the pool test kit. Chlorine levels higher than the test kit range (i.e., over-range samples) can be measured using dilution. True high free chlorine range can cause interference with other chemical parameters. 2. Proper operator records were not being documented daily including but not limited to: day/month/year, staff responsible, time of tests etc. Discussed improvements required. Request that chemical parameters and automated controller readings be tested/documented twice daily (a.m. & p.m.) or more often as deemed necessary. If chemical parameters are not within legislative requirements, ensure the basin is closed to the public until corrective actions have been taken and chemical parameters are within legislative requirements.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Risk Management Inspection
0 infractions
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 03/06/2026 was unsatisfactory: Total coliforms present & HPC 340 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 26/05/2026 was unsatisfactory: HPC 350 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 01/06/2026 for the swimming pool was unsatisfactory: HPC 140 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 01/06/2026 for the swimming pool was unsatisfactory: HPC 140 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 26/05/2026 was unsatisfactory: HPC 350 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 26/05/2026 was unsatisfactory: HPC 350 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 01/06/2026 for the swimming pool was unsatisfactory: HPC 140 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 26/05/2026 was unsatisfactory: HPC 350 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected 25/09/2025 [25EN-269E00074] was unsatisfactory: HPC 160 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample results collected on 03/09/2024 [ID #: 24EN-247E00043] was unsatisfactory: HPC 1080 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Floating skimmer basket had some paper and leaves debris in it. This was cleaned during the time of inspection.Make sure to regularly monitor and clean the skimmer baskets for any debris or garbage deposited in it.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 15/07/2024 [ID #: 24EN-197E00042] was unsatisfactory: HPC 110 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Initial Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate was below the minimum reading levels on the Flo-Vis. Increase flow rate and ensure it does not exceed 106 GPM.Repair the leak on the chlorine return line in the mechanical room.The water level is too low. Increase water levels to allow for sufficient skimming action.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Nearby inspected facilities
- 565 Griesbach Parade NW - Aquatic Common Area
565 Griesbach Parade NW Edmonton AB T5E 1Y8
7 inspections
- Scoop N Roll Griesbach
103 - 9920 137 Avenue NW Edmonton AB T5E 6W1
6 inspections
- Fairfield Inn & Suites - Breakfast Area
581 Griesbach Parade NW Edmonton AB T5E 6W1
1 inspection
- Fairfield Inn & Suites - Swimming Pool
581 Griesbach Parade NW Edmonton AB T5E 6W1
30 inspections
- Fairfield Inn & Suites - Aquatic Common Area
581 Griesbach Parade NW Edmonton AB T5E 6W1
4 inspections
- Sicilian Pasta Kitchen North Ltd.
106 - 9810 137 Avenue NW Edmonton AB T5E 4H5
1 inspection
- First Step Daycare - Kitchen
101 - 9810 137 Avenue NW Edmonton AB T5E 6W1
7 inspections
- First Step Daycare - Daycare
101 - 9810 137 Avenue NW Edmonton AB T5E 6W1
9 inspections