Element Calgary Airport - Hot Tub
2855 Sunridge Way NE Calgary AB T1Y 7K7 · Aquatic Facility
15 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- April 27, 2026, water sample was not processed. No date and time on the requisition form.Please resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- There was no clock by the whirlpool area. A clock was placed in the whirlpool area during the inspection.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on April 3, 2025, was not sampled because there was no identification number on the bottle.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample submitted on November 29, 2024, was not processed because it was received during the weekend/holiday without approval.-Please submit another sample and ensure to follow proper sampling procedures.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
4 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH was too high, measured at 7.9 at the time of inspection.-Please reduce and maintain pool pH between 6.8 and 7.6.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was over 180 milligram per litre.-Please lower and maintain total alkalinity between 60-180 milligram per litre.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not in good working condition.-Please fix or replace the indicated equipment to ensure proper pool operation and maintenance.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was measured at 40.6 degrees Celsius.-Please reduce and maintain the pool temperature below 40 degrees Celsius.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH was too high, measured at 8.07 at the time of inspection.-Please reduce and maintain pool pH between 6.8 and 7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not in good working condition.-Please fix or replace the indicated equipment to ensure proper pool operation and maintenance.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was measured at 40.6 degrees Celsius.-Please reduce and maintain the pool temperature below 40 degrees Celsius.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Whirlpool water sample collected on March 28, 2024, had Pseudomonas aeruginosa isolated per 100mL.-Please treat the whirlpool in accordance with AHS treatment protocol and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Whirlpool water sample collected on March 28, 2024, showed HPC was enumerated at 120 CFU/mL.-Please resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
4 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Hot tub water pH was measured at 7.9.-Please maintain the pool pH between 6.8 and 7.6 to ensure good pool water balance.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. THE FLOW METER WAS NOT WORKING.REPAIR/REPLACE FLOW METER.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment compliance plan for the hot tub was not completed.-Please complete the hot tub anti-entrapment compliance plan and submit to the district inspection for evaluation including all the required documentation.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Some tiles were missing in the hot tub basin beside the left floor drain cover.-Please replace the missing basin tiles.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. THE FLOW METER WAS NOT WORKING.REPAIR/REPLACE FLOW METER.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
4 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- 1. The whirlpool pH was measured at 7.8 during the inspection.-Please maintain the pool pH between 6.8 and 7.6 as required in the Pool Standards.2. There was no chlorine in the whirlpool, the free available chlorine was measured to be 0.00ppm.-Please adjust the whirlpool water chemical and ensure the free available chlorine is maintained above 2.0 milligram per litre at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. THE FLOW METER WAS NOT WORKING.REPAIR/REPLACE FLOW METER.Observed during the previous inspection.2. The automatic chemical controller for the pool was not in good working condition, the automatic controller was not feeding chemicals into the pool.-Please replace or repair the automatic controller and ensure it is in good working condition.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The whirlpool water was cloudy.-Please treat the whirlpool water to eliminate any possible source of contamination and to restore clarity.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Layers of scum were observed on the whirlpool basin and in the skimmers.-Please drain the whirlpool, clean including scrubbing and sanitize the basin and the skimmers to remove all scum.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?