Staybridge Suites - Whirlpool

2825 Sunridge Way NE Calgary AB T1Y 7E4 · Aquatic Facility

Inspection summary

Staybridge Suites - Whirlpool has been inspected 20 times by Alberta Health Services (Environmental Public Health) since October 20, 2023. The most recent inspection, on October 1, 2026, recorded 4 infractions.

5 of 20 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 14 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 22 times across 15 separate inspections, most recently on October 1, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 3 times across 3 separate inspections, most recently on October 7, 2024. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 2 times across 2 separate inspections, most recently on October 1, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 7 times across 6 separate inspections, most recently on October 1, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

20 inspections

  1. Monitoring Inspection

    4 infractions

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • The whirlpool circulation flow rate was measured at 79.25 GPM. The calculated turnover time is approximately 23.33 minutes, which does not meet the required 20-minute turnover period. The calculated filtration rate is approximately 16.17 GPM/ft², which exceeds the applicable maximum filtration rate of <12.5 GPM/ft² for whirlpools.The minimum flow rate required to achieve the specified turnover period is 92.46 GPM. Increase the flow rate to meet the calculated minimum of 92.46 GPM or the manufacturer’s recommended flow rate of 100 GPM, as applicable. Ensure that water chemistry and bacteriological test results also meet the required standards.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The handrails were observed to be slightly loose. The operator was advised to securely tighten and stabilize the handrails to ensure they are secure for patrons.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The manual water testing log did not include the time at which each test was conducted. The operator was advised to add a column to the testing log to record the time of each water test.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • No log documenting water contamination incidents was available onsite at the time of inspection. The operator was advised to maintain a record of all contamination incidents, including the nature of the incident and the corrective actions taken. Please refer to the attached Water Contamination Response Log document for additional information.
  2. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated system pH reading not consistent with manual reading.- Clean probes and calibrate if needed.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The Free Available Chlorine (FAC) was not tested accurately when above 5 ppm.If the FAC reading is high, the operator should dilute the sample and retest to obtain an accurate value.Once the actual FAC level is confirmed, appropriate corrective actions should be taken to reduce it to within the acceptable standard.2. Records show a pH value of 7.8, which is outside the acceptable range.No corrective action was documented.Ensure appropriate measures are taken to adjust the pH and bring it within the required.3. Combined chlorine tests were not conducted.Please ensure that combined chlorine is measured as part of routine water quality monitoring to assess disinfection by-products.
  3. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on April 7, 2026, was unsatisfactory with the presence of Pseudomonas aeruginosa.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample (26ES-093E00013) submitted on April 7, 2026 for the whirlpool, was unsatisfactory as Total Coliforms was present (acceptable limit is absent per 100mL). Please treat the water, chemically balance and submit another water sample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on April 7, 2026, was unsatisfactory with the HPC being measured at >57,000 CFU/mL.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated system pH reading not consistent with manual reading.- Clean probes and calibrate if needed.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The Free Available Chlorine (FAC) was not tested accurately when above 5 ppm.If the FAC reading is high, the operator should dilute the sample and retest to obtain an accurate value.Once the actual FAC level is confirmed, appropriate corrective actions should be taken to reduce it to within the acceptable standard.2. Records show a pH value of 7.8, which is outside the acceptable range.No corrective action was documented.Ensure appropriate measures are taken to adjust the pH and bring it within the required.3. Combined chlorine tests were not conducted.Please ensure that combined chlorine is measured as part of routine water quality monitoring to assess disinfection by-products.
  4. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample (26ES-093E00013) submitted on April 7, 2026 for the whirlpool, was unsatisfactory as Total Coliforms was present (acceptable limit is absent per 100mL). Please treat the water, chemically balance and submit another water sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated system pH reading not consistent with manual reading.- Clean probes and calibrate if needed.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The Free Available Chlorine (FAC) was not tested accurately when above 5 ppm.If the FAC reading is high, the operator should dilute the sample and retest to obtain an accurate value.Once the actual FAC level is confirmed, appropriate corrective actions should be taken to reduce it to within the acceptable standard.2. Records show a pH value of 7.8, which is outside the acceptable range.No corrective action was documented.Ensure appropriate measures are taken to adjust the pH and bring it within the required.3. Combined chlorine tests were not conducted.Please ensure that combined chlorine is measured as part of routine water quality monitoring to assess disinfection by-products.
  5. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated system pH reading not consistent with manual reading.- Clean probes and calibrate if needed.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The Free Available Chlorine (FAC) was not tested accurately when above 5 ppm.If the FAC reading is high, the operator should dilute the sample and retest to obtain an accurate value.Once the actual FAC level is confirmed, appropriate corrective actions should be taken to reduce it to within the acceptable standard.2. Records show a pH value of 7.8, which is outside the acceptable range.No corrective action was documented.Ensure appropriate measures are taken to adjust the pH and bring it within the required.3. Combined chlorine tests were not conducted.Please ensure that combined chlorine is measured as part of routine water quality monitoring to assess disinfection by-products.
  6. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • ID 25ES275E00187Sample collection date was Oct 8, 2025- Water sample submitted was received more than 24 hours of collection.- Resampling advised.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • ID 25ES275E00809Water sample submitted was received more than 24 hours of collection.
  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • ID 25ES275E00809Water sample submitted was received more than 24 hours of collection.
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on February 11, 2025, was not tested because it was received more than 24 hours after collection. This was the last water sample submitted for bacteriological water analysis as of February 24, 2025. Thus, please submit a water sample for bacteriological water analysis immediately. Please be advised that water samples must be submitted weekly, as required.
  10. Risk Management Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample submitted on January 17, 2025, was processed because the time of collection was not indicated.-Please submit another sample and ensure to follow proper sample procedures.
  12. Risk Management Inspection

    0 infractions

  13. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on October 4, 2024, showed that Heterotrophic Plate Count (HPC) was enumerated at 120CFU/mL.-Please take and submit another sample, ensure proper procedure is followed to prevent contamination. Label as resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was measured at 3.78ppm at the time of the inspection.-Please lower and maintain the combined chlorine as low as possible to ensure bathers' comfort.*Outstanding violation from last inspection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pool filtration rate was too fast, calculated at 21.6 GPM/sq. ft.-Please lower the filtration rate in compliance with the pool standards or manufacturer's recommendation.*Outstanding violation from last inspection.
  14. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was measured at 3.78ppm at the time of the inspection.-Please lower and maintain the combined chlorine as low as possible to ensure bathers' comfort.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pool filtration rate was too fast, calculated at 21.6 GPM/sq. ft.-Please lower the filtration rate in compliance with the pool standards or manufacturer's recommendation.
  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on August 23, 2024, was not processed because there was no identification number on the bottle.-Please take and submit another sample.
  16. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas IsolatedTreat and submit a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC of 3200 CFU/mL Treat and submit a resample.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine reading was not being maintained at the lowest possible level. Combined chlorine level tested at 6.48 ppm at the time of inspection.- Maintain combined chlorine levels at the lowest level possible to maximize bather comfort.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • The pool operator who operates and maintains the pool on a day-to day basis was not sufficiently qualified.-Please ensure the pool operator who maintains the pool operations on daily basis is sufficiently qualified.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Chemical levels are not tested and recorded properly, the review of the records showed there was no further record testing performed after chemicals was added to the whirlpool to show that water was properly balance and safe for use.-Please ensure proper testing and recording of pool water chemical parameters daily, before and after addition of chemicals, including time and quantity of any chemical additions.
  19. Risk Management Inspection

    0 infractions

  20. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The automated chemical feeding and monitoring system was not in a good working order and was not maintaining proper chemical levels. Free chlorine level was so high that it could not be tested. -Please repair or replace the indicated equipment to ensure proper pool operation and chemical balance.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. Jet flow meter was reading outside of the scale. - Replace the flow meter.