Staybridge Suites - Swimming Pool
2825 Sunridge Way NE Calgary AB T1Y 7E4 · Aquatic Facility
30 inspections
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample (26ES-160E00861) collected on June 9, 2026, was unsatisfactory was Total Coliforms was present. Please treat the water, chemically balance and submit another water sample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 220Sample ID 26ES026E00055Collection date 26 Jan 2026Resampling advised.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- ID 26ES009E00165TC present Resampling advised.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 3600Sample date Jan 1, 2026ID 26ES009E00165
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The floating rings in the pool skimmer were found to be broken.- Replace the damaged floating rings.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- ID 25ES275E00188Sample collection date was Oct 8, 2025- Water sample submitted was received more than 24 hours of collection.- Resampling advised.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- - ID 25ES275E00810Water sample submitted was received more than 24 hours after the collection date.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- - ID 25ES275E00810Water sample submitted was received more than 24 hours after the collection date.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on July 30, 2025, was unsatisfactory with the presence of Total Coliforms.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on July 30, 2025, was unsatisfactory with an HPC of 520 CFU/mL.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on February 11, 2025, was not tested because it was received more than 24 hours after collection. This was the last water sample submitted for bacteriological water analysis as of February 24, 2025. Thus, please submit a water sample for bacteriological water analysis immediately. Please be advised that water samples must be submitted weekly, as required.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample submitted on January 21, 2025, showed that Heterotrophic Plate Count was enumerated at 3020 CFU/mL.-Please treat the pool according to AHS guidelines and submit another water sample, label as resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample submitted on January 17, 2025, was processed because the time of collection was not indicated.-Please submit another sample and ensure to follow proper sample procedures.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample collected on November 15, 2024, was not processed because there was no identification number on the bottle.-Please resample and follow proper sampling protocol.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not properly calibrated.-Please calibrate the indicated equipment to ensure proper pool operation and maintenance.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The free available chlorine was inadequate, measured at 0.44 milligram per litre.-Please increase and maintain the pool chlorine at or above 1.0 milligram per litre.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not properly calibrated.-Please calibrate the indicated equipment to ensure proper pool operation and maintenance.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The person in charge of the pool at the time of the inspection does not know how to use the facility's new pool kit.-Please ensure the person in charge of the pool at all times is properly trained and have pool's operator certification.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not properly calibrated.-Please calibrate the indicated equipment to ensure proper pool operation and maintenance.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The free available chlorine in the pool was over the range of pool's kit measurement.-Please reduce the chlorine in the pool so that it is measurable.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
4 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine readings are not being maintained at the lowest possible level, measured at 1.43 ppm at the time of inspection.-Please lower and maintain combined chlorine as low as possible.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Circulation pump was not in good working condition.-Please repair or replace the pump and ensure its good working condition.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not in good working condition.-Please fix or replace the indicated equipment to ensure proper pool operation and maintenance.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The pool water was cloudy.-Please resolve the water cloudiness to ensure the pool is physically and chemically safe for use.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH of the pool was measured at 7.72 at the time of the inspection.-Please adjust the pool chemistry and maintain pH between 6.8 and 7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring controller was not in good working condition.-Please fix or replace the indicated equipment to ensure proper pool operation and maintenance.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
4 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine reading was not being maintained at the lowest possible level. Combined chlorine level tested at 2.43 ppm at the time of inspection.- Maintain combined chlorine levels at the lowest level possible to maximize bather comfort.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment was not maintained in good working condition or calibrated regularly to ensure it is working properly, the pool operator was manually adding chemicals to the pool every day.-Please repair or replace the automatic controller to ensure pool's water is continually disinfected to ensure patrons' safety.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- The pool operator who operates and maintains the pool on a day-to day basis was not sufficiently qualified.-Please ensure the pool operator who maintains the pool operations on daily basis is sufficiently qualified.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical levels are not tested and recorded properly, the review of the records showed initial measurement of chlorine concentration at zero ppm everyday, there was no further record testing performed after chemicals was added to the pool to show that water was properly balance and safe for use.-Please ensure proper testing and recording of pool water chemical parameters daily, before and after addition of chemicals, including time and quantity of any chemical additions.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Pool water sample was not being taken and submitted to ProvLab weekly, last water sample result was on 2023-10-18.-Please ensure pool water sample is submitted to ProvLab weekly to assure water quality.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. A bacteriological water sample was not submitted the first week of September when pool was open. - Submit water samples every week.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- 1. Combined chlorine readings are not being maintained at the lowest possible level. Combined chlorine level tested at 2.22 ppm at the time of inspection.- Maintain combined chlorine levels at the lowest level possible to maximize bather comfort.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The automated chemical feeding and monitoring system was not calibrated adequately, and its readings were inconsistent with manual readings. Manual pH reading was 7.0 and automated system reading was 7.6 at the time of inspection. - Repair, replace and/or calibrate the automatic chemical feeding and monitoring equipment and ensure this equipment is in good working condition.2. Main drain valve was fully open. - Keep main drain valve only 20-30% open to maximize surface recirculation.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. Chemical levels are not tested and recorded daily. Several days of testing was missing in a daily log. - Test and record chemical levels on daily basis. 2. Automated system readings were not being recorded. - Record daily automated system readings for ORP and pH. 3. Free chlorine level at the time of inspection tested 13.48 ppm but staff recorded only 5 ppm because their test kit does not read higher levels. - When free chlorine tests at 5 ppm, staff need to dilute the water sample to verify how much higher the chlorine level is. Or obtain a test kit that reads higher chlorine levels.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The pool weekly water sample was last submitted in April 2023.Please immediately take and submit water sample and ensure pool water sample is submitted to the ProvLab weekly to assure microbiologically safe water.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool water chemical parameters, such as total chlorine, free available chlorine, combined chlorine and pH, were not being recorded daily.-Please record all water chemical parameters daily to ensure properly water balance and monitoring.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- There was no disinfectant in the pool water, the water free available chlorine was measured at 0.05ppm.-Please maintain the pool free available chlorine at above 1.0 milligram per litre.The pool water free available chlorine was later measured at 1.0ppm after the automatic feeder injector was repaired.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The pool was cloudy, and lot of dirt particles were seen floating in the water and skimmers.-Please treat and resolve the water cloudiness, and vacuum to remove all particles from the pool water.The pool was voluntarily closed until water cloudiness concern is resolved.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool water chemical parameters, such as total chlorine, free available chlorine, combined chlorine and pH, were not being recorded daily.-Please record all water chemical parameters daily to ensure properly water balance and monitoring.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?