Element Calgary Airport - Swimming Pool

2855 Sunridge Way NE Calgary AB T1Y 7K7 · Aquatic Facility

17 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample (26ES-049E00373) collected on February 17, 2026, came back unsatisfactory as the HPC was elevated (890 CFU/mL). The maximum allowable level is 100CFU/mL of HPC.Please resample the swimming pool as soon as possible.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 2680Collection date Sept 18, 2025ID 25ES26E00047Resampling advised
  5. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate was measured at 63 GPM. The turnover period was calculated to be 4.32 hours as per the measured flow rate. The flow rate was adjusted to 80 GPM during the inspection. The new turnover period was re-calculated to be 3.4 hours. Please ensure that the flow rate is between 68-108 GPM at all times.
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • **UNSATISFACTORY WATER SAMPLE TEST RESULT**1. The water sample collected on May 8, 2025, was unsatisfactory with an HPC of 2,150 CFU/mL. Another water sample must be submitted immediately.2. The water sample collected on May 15, 2025, was unsatisfactory with an HPC of 3,460 CFU/mL. Another water sample must be submitted immediately.
  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • **UNSATISFACTORY WATER SAMPLE TEST RESULT**The water sample collected on May 8, 2025, was unsatisfactory with an HPC of 2150 CFU/mL.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample submitted on November 29, 2024, was not processed because it was received during the weekend/holiday without approval.-Please submit another sample and ensure to follow proper sampling procedures.
  11. Risk Management Inspection

    0 infractions

  12. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter reading was 40 GPM, and turnover period was calculated at 6.80 hours.-Please increase the pool flow rate to ensure proper turnover for water disinfection and filtration.
  13. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pool water sample collected on 2024-01-18 showed that Total Coliforms was present in 100mL.-Please treat the pool in accordance with AHS unsatisfactory pool water sample and resubmit water sample.
  14. Risk Management Inspection

    0 infractions

  15. Risk Management Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The pool drain covers had expired and the anti-entrapment compliance plan was yet to be completed/submitted for assessment.-Please replace the pool's drain covers, ensure they are ANSI/APSP-16 2011 compliant and complete the anti-entrapment compliant assessment.
  16. Risk Management Inspection

    0 infractions

  17. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • 1. The pool pH was measured at 7.7 during the inspection.-Please maintain the pool pH between 6.8 and 7.6 as required in the Pool Standards.2. The free available chlorine was measured to be 0.11ppm.-Please adjust the pool water chemical and ensure the free available chlorine is maintained above 1.0 milligram per litre at all times.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automatic chemical controller was not in good working condition, the automatic controller was not feeding chemicals into the pool nor was it displaying the correct water chemical parameters.-Please replace or repair the automatic controller and it is in good working condition.