Skip to content
Loading map…

Holiday Inn Express Red Deer - Swimming Pool

2803 50 Avenue Red Deer AB T4R 1H1 · Aquatic Facility

Inspection summary

Holiday Inn Express Red Deer - Swimming Pool has been inspected 15 times by Alberta Health Services (Environmental Public Health) since May 3, 2024. The most recent inspection, on May 19, 2026, recorded 1 infraction.

5 of 15 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 12 times across 10 separate inspections, most recently on May 19, 2026. For example: Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded once on June 2, 2025. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

15 inspections

  1. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There is a leak on the plumbing supplying the water slide with water causing a small pool of water on the deck behind the slide stairs. The pooled water is out of the way and doesn't pose a slip hazard but long-term pooling can cause water damage to the floor and wall. Please located the leak and repair it.May 19/26: the pool operator indicated that a part has been ordered and once it arrives, the leak will be repaired.
  2. Monitoring Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There is a leak on the plumbing supplying the water slide with water causing a small pool of water on the deck behind the slide stairs. The pooled water is out of the way and doesn't pose a slip hazard but long-term pooling can cause water damage to the floor and wall. Please located the leak and repair it.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Lab results for water sample unsatisfactory with HPC count at 150 CFU/ml (>100 CFU/ml). Please resample and retest.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    2 infractions

    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • Pool safety hook is unustable due improper attachment to the main staff, resulting in a loose connection that requires minimal effort to take apart.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily chemical tests and logging were missing for June 1 and 2. Last test noted was on May 31.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC counts were acceptable <100 CFU/ml.
  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory HPC counts (320 CFU/ml) were noted in the previous water sampling result. Advised pool operator to resample and gave instructions on pool treatment methods if necessary.
  10. Risk Management Inspection

    0 infractions

  11. Risk Management Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The covers of the submerged main drain suction outlets in the swimming pool are not properly installed. One cover has a total of 5 screwed installed and one cover has a total of 6 installed now (manufacturer requires four screws). The screws used to install the covers are not consistent (variable types/style).
  12. Demand Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The submerged suction outlet covers are expired based on the installation dates provided by the anti entrapment plan.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The submerged suction outlets in the swimming pool are improperly secured. Specially there are two screws missing from one of the submerged outlet cover (main drain cover) and different types of screws were observed to be installed for the drain covers.
  13. Demand Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The submerged suction outlets in the swimming pool are improperly secured. Specially there are two screws missing from one of the submerged outlet cover (main drain cover) and different types of screws were observed to be installed for the drain covers.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The submerged suction outlet covers are expired based on the installation dates provided by the anti entrapment plan.
  14. Risk Management Inspection

    0 infractions

  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool sample result for sample collected on Apr 30 2024 came back with result of T C Absent and HPC 250I spoke with Rob onsite and informed him of the result and requested the pool to be shock treated and a sample submitted next week. Rob will close the pool and shock treat today and a sample sent in next week.

Nearby inspected facilities

Own this business? Add a badge to your website