Travelodge by Wyndham Red Deer - Swimming Pool
2807 50 Avenue Red Deer AB T4R 1H6 · Aquatic Facility
5 inspections
- Demand Inspection
4 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Mechanical room displayed readings:ORP - 646 mVpH - 7.46Tested readings:FAC - 0.68 ppmpH - 7.63
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Surface skimmers were not adequately removing contaminants on the surface of the water. Spiders and other floating paints were observed flowing around and near the floating weir, but not into the weir itself to be removed. Please adjust the water level in the pool so that the surface skimmers may filter out and remove contaminants from the pool.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Pool basin floor and corners has visible grime and requires a good cleaning.Pool skimmer was observed to be dirty and needed cleaning after the cover was removed. Please ensure that the pool is maintained in a clean and sanitary condition.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Written procedures for responding to fecal incidents are not available. Pool operator understood proper procedure for cleaning in response to incidents.Please create a written procedure for handling fecal and diarrheal incidents in this pool for patron safety.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate was too high. Please ensure the filtration rate is less than 15 gallons per minute per square feet.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Pool sample result for sample collected on Apr 30 2024 came back with result of T C Absent and HPC 250May 10/24: Second bacteriological result with high HPC. Count read 260CFUs. Please shock the pool again to 10ppm then rebalance the water chemistry and resubmit samples next week.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate was too high. Please ensure the filtration rate is less than 15 gallons per minute per square feet.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Pool sample result for sample collected on Apr 30 2024 came back with result of T C Absent and HPC 250May 10/24: Second bacteriological result with high HPC. Count read 260CFUs. Please shock the pool again to 10ppm then rebalance the water chemistry and resubmit samples next week.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The measured alkalinity was above 180 mg/l. Please ensure alkalinity is adjusted and measures between 60 - 180 mg/l
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate was too high. Please ensure the filtration rate is less than 15 gallons per minute per square feet.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Pool sample result for sample collected on Apr 30 2024 came back with result of T C Absent and HPC 250HPC above 100I spoke with front desk attendant onsite and she called Gene the maintenance guy. I informed him of the result and requested the pool to be shock treated and a sample submitted next week. Gene will close the pool and shock treat today and a sample sent in next week.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The measured alkalinity was above 180 mg/l. Please ensure alkalinity is adjusted and measures between 60 - 180 mg/l
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate was too high. Please ensure the filtration rate is less than 15 gallons per minute per square feet.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?