Holiday Inn Express & Suites Calgary South - Swimming Pool
12025 Lake Fraser Drive SE Calgary AB T2J 7G5 · Aquatic Facility
35 inspections
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Water chemistry was not recorded today (or other days) when main, responsible person is away.-more people need to be trained with water testing. This needs to be completed daily and preferably multiple times per day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
5 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The pool drain covers are expired with a date of Jan 31, 2023.-hire a contractor to complete a NEW anti-entrapment plan and install NEW drain covers immediately.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Water chemistry was not recorded today (or other days) when main, responsible person is away.-more people need to be trained with water testing. This needs to be completed daily and preferably multiple times per day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Water chemistry was not recorded today (or other days) when main, responsible person is away.-more people need to be trained with water testing. This needs to be completed daily and preferably multiple times per day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
7 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on February 13, 2026, had total coliforms present. Please treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Feb 20, 2026 had Total Coliforms present.ID:26ES-051E00180-as this is the 2nd consecutive unsatisfactory water sample result, the swimming pool must be closed until a satisfactory water sample result is obtained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample result Feb 24, 2026 - not processed by lab as there was no collection date/time.ID: 26ES-055E00565
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.8, however, the controller stated 7.16
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
7 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on February 13, 2026, had total coliforms present. Please treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Feb 20, 2026 had Total Coliforms present.ID:26ES-051E00180-as this is the 2nd consecutive unsatisfactory water sample result, the swimming pool must be closed until a satisfactory water sample result is obtained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample result Feb 24, 2026 - not processed by lab as there was no collection date/time.ID: 26ES-055E00565
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Water chemistry was not recorded today (or other days) when main, responsible person is away.-more people need to be trained with water testing. This needs to be completed daily and preferably multiple times per day.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
6 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on February 13, 2026, had total coliforms present. Please treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Feb 20, 2026 had Total Coliforms present.ID:26ES-051E00180-as this is the 2nd consecutive unsatisfactory water sample result, the swimming pool must be closed until a satisfactory water sample result is obtained.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.8, however, the controller stated 7.16
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller system was not accurate.-repair/replace the controller/probes; call the pool company to have it serviced or repaired/replaced.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The equalizer line was missing a cover.-install a cover AND/OR provide evidence that the line is permanently disabled.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1 pool ladder was missing and the holes on the pool deck were stuffed with cloths.-the new ladder was already ordered.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on February 13, 2026, had total coliforms present. Please treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Feb 20, 2026 had Total Coliforms present.ID:26ES-051E00180-as this is the 2nd consecutive unsatisfactory water sample result, the swimming pool must be closed until a satisfactory water sample result is obtained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on February 13, 2026, had total coliforms present. Please treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00010-submit another sample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00010-submit another sample
- 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
- The Free Available Chlorine measured 24.3 mg/L.-lower the free available chlorine.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Records were not accurate and was missing: time, chemicals added, clarity, temperature, controller values, Alkalinity-create and implement new recordkeeping system.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00010-submit another sample
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine measured 2.4 ppm.-use non-chlorinated oxidizing products to oxidize the combine chlorine.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Nov 28, 2025 had Total Coliform present.-treat and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine measured 2.4 ppm.-use non-chlorinated oxidizing products to oxidize the combine chlorine.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine measured 2.4 ppm.-use non-chlorinated oxidizing products to oxidize the combine chlorine.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine measured 2.4 ppm.-use non-chlorinated oxidizing products to oxidize the combine chlorine.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine measured 4.3ppm; free chlorine was 4.2ppm.-super chlorinate (or use non-chlorinated oxidizing products) the pool to oxidize the combine chlorine.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1) The filtration rate of 20 gpm/sqft was too fast. The flow rate was 98gpm.-adjust the flow rate2) The valves for the skimmers and main drains were positioned at 100%.-main drain should be set to 20% and skimmer valve set to 80%.3) The ORP probe was reading 917 but set to 720 mV-the probe appears need cleaning/replacement or servicing.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Aug 15, 2025 had Total Coliform present (per 100mL)-treat and resample-ID: 25ES-227E00238
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The pool water sample collected on August 8, 2025 resulted in 920 CFU/mL Heterotrophic plate count.ID: 25-ES-220E00202-treat and resample
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The pool water sample collected on August 8, 2025 resulted in 920 CFU/mL Heterotrophic plate count.ID: 25-ES-220E00202-treat and resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on July 25, 2025 had a HPC of 1820 CFU/mL-ID 25ES-206E00149-treat and resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample collected on Feb 28 resulted in the PRESENCE of Total Coliform.Req ID: 2568286, ID:25ES-059E00132-Treat and resample the pool water.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample collected on Jan 3/25 had Total Coliforms present.- Treat the pool water and resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological waters sample collected on Nov 15/24 had Total coliform present.- Treat the pool water and resample.Bacteriological waters sample collected on Nov 22/24 had Total coliform present.- Verbal order to close the pool was given to Johnny, pool operator. - Discussed further treating of the pool water and submitting a resample. The pool must remain closed until a satisfactory water sample is obtained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological waters sample collected on Nov 15/24 had Total coliform present.- Treat the pool water and resample.Bacteriological waters sample collected on Nov 22/24 had Total coliform present.- Verbal order to close the pool was given to Johnny, pool operator. - Discussed further treating of the pool water and submitting a resample. The pool must remain closed until a satisfactory water sample is obtained.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 33 ppm. - Maintain total alkalinity between 60-180 ppm.Combined chlorine measure over 2 ppm. - Maintain combined chlorine at the lowest level possible.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- There was a large scum line on pool walls. - Clean pool walls regularly.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological waters sample collected on Nov 15/24 had Total coliform present.- Treat the pool water and resample.Bacteriological waters sample collected on Nov 22/24 had Total coliform present.- Verbal order to close the pool was given to Johnny, pool operator. - Discussed further treating of the pool water and submitting a resample. The pool must remain closed until a satisfactory water sample is obtained.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine measured 2.02 ppm. - Maintain combined chlorine at the lowest level possible.- Combined chlorine is not being tested accurately.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological waters sample collected on Nov 15/24 has Total coliform present.- Treat the pool water and resample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 33 ppm. - Maintain total alkalinity between 60-180 ppm.Combined chlorine measure over 2 ppm. - Maintain combined chlorine at the lowest level possible.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- There was a large scum line on pool walls. - Clean pool walls regularly.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 33 ppm. - Maintain total alkalinity between 60-180 ppm.Combined chlorine measure over 2 ppm. - Maintain combined chlorine at the lowest level possible.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- There was a large scum line on pool walls. - Clean pool walls regularly.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 33 ppm. - Maintain total alkalinity between 60-180 ppm.Combined chlorine measure over 2 ppm. - Maintain combined chlorine at the lowest level possible.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- 1. Pool water was cloudy. - Ensure that pool water is adequately clear. * Main drains were still visible*2. There was a large scum line on pool walls. - Clean pool walls regularly.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on June 14/24 had HPC+ 210 cfu/ml. - Reviewed water chemistry and sampling with Johnny, pool operator. - The pool operator will treat the pool water and submit a resample to Prov, Laboratory.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system is still overfeeding chlorine. Calibrate the automated system so it maintains free chlorine between 2-5 ppm. According to the daily written records, free chlorine levels in the past several days were between 3- 5 ppm. - The system was calibrated by the pool operator again.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample collected on March 1/24 had Total Coliforms present. - Treat the pool water and submit a resample to Prov, Laboratory.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system is still overfeeding chlorine. Calibrate the automated system so it maintains free chlorine between 2-5 ppm. According to the daily written records, free chlorine levels in the past several days were between 3- 5 ppm. - The system was calibrated by the pool operator again.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system is still overfeeding chlorine. Calibrate the automated system so it maintains free chlorine between 2-5 ppm. According to the daily written records, free chlorine levels in the past several days were between 3- 5 ppm. - The system was calibrated by the pool operator again.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system is still overfeeding chlorine. Calibrate the automated system so it maintains free chlorine between 2-5 ppm. - The probes were cleaned and system calibrated by Ecolab.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system is overfeeding chlorine. Calibrate the automated system so it maintains free chlorine between 2-5 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Sample collected and analyzed on 202312-22 shows the presence of total coliforms. Please treat the water and resample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 42 ppm. - Maintain total alkalinity between 60-180 ppm. - Ensure that staff understand what adequate alkalinity level is and are adding enough sodium bicarbonate for optimal level.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?