Holiday Inn Express & Suites Calgary South - Whirlpool

12025 Lake Fraser Drive SE Calgary AB T2J 7G5 · Aquatic Facility

27 inspections

  1. Risk Management Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine measured 0.5mg/L-chlorine pump was turned off; pump turned back on. The operator was concerned the free available chlorine was too high yesterday.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir in the hot tub was missing.-obtain a floating weir or skimming device.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller measured ORP=641 mV, pH=7.32 ppm but the manual recordings were: 0.5 mg/L of Chlorine, and pH of 7.65.-contact the controller manufacturer and request service/repair/replacement.-the controller should be similar readings to manual readings.-pump for chlorine was shut off. If the controller was working properly, you wouldn't need to turn off any acid or chlorine pumps.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Water chemistry testing/recording was not being completed when pool maintenance staff was not working.-more staff must be involved in monitoring and maintaining the pool and hot tub.
  2. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH on the water in the hot tub was 7.96-adjusted during inspection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller was calling for more chlorine and acid with readings of ORP=726 mV, pH=7.30 ppm but the manual recordings were: 15.5 mg/L of Chlorine, and pH of 7.96.-contact the controller manufacturer and request service/repair/replacement.-the controller should be similar readings to manual readings.
  3. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected 01/29/206 and received 01/30/26 was unsatisfactory with total coliforms (TC) present.Please treat and submit a re-sample.
  4. Demand Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured 42 mg/L
  5. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on January 16, 2026 had Total Coliforms present.-treat and resampleID: 26ES-016E00184
  6. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00009-submit another sample
  7. Demand Inspection

    6 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00009-submit another sample
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH measured 7.97-adjust pH and ensure it is between 6.8 and 7.6
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity (TA) was 985 ppm.-adjust the TA to 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller read were inconsistent with manual testing. The automated controller reading for pH was 7.34 and ORP was 706. The manual test result was pH 7.97 and 56.7 mg/L free available chlorine.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The Free Available Chlorine measured 56.7 mg/L.-lower the free available chlorine.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Records were not accurate and was missing: time, chemicals added, clarity, temperature, controller values, Alkalinity-create and implement new recordkeeping system.
  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample that was collected on Dec 12, 2025 was not processed by the lab since it was dropped off on the weekend.ID: 25ES-347E00009-submit another sample
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Nov 24, 2025 resulted in the presence of Total Coliform. -treat and resample.ID:25ES-329E00604
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Nov 28, 2025 had Total Coliform present. -Hot tub was ordered CLOSED as there were consecutive unsatisfactory results. -drain and treat the hot tub. Resample and wait for confirmation that the sample is satisfactory.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Dec 3, 2025 resulted had Total Coliforms present.-treat, resample.-WP to remain closed
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
  11. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Nov 24, 2025 resulted in the presence of Total Coliform. -treat and resample.ID:25ES-329E00604
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Nov 28, 2025 had Total Coliform present. -Hot tub was ordered CLOSED as there were consecutive unsatisfactory results. -drain and treat the hot tub. Resample and wait for confirmation that the sample is satisfactory.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
  12. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Nov 24, 2025 resulted in the presence of Total Coliform. -treat and resample.ID:25ES-329E00604
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected and received on November 21, 2025, was not processed as there was no identification number on the sample bottle. Please submit a new sample.
  14. Monitoring Inspection

    0 infractions

  15. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Sep 12, 2025 had Total Coliform PRESENT.-treat and resampleID: 25ES-25E00164
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  16. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • There was no TIME OF COLLECTION noted on the requisition, so the sample was rejected.-August 15, 2025 collectionID: 25ES-227E00200
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  17. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • There was no identification on the bottle so the sample was rejected.-July 25, 2025 collectionID: 25ES-206E00182
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  18. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  19. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on May 16, 2025 resulted in the presence of Total Coliform.-treat and resample-req id: 3033413, ID: 25ES-136E00170
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  20. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample collected on Jan 31, 2025, shows the presence of total coliforms, and Pseudomonas aeruginosa- Treat the hot tub water and submit a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Bacteriological sample collected on Jan 31, 2025, resulted in 10,240 CFU/mL.- Treat the hot tub water and submit a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • “sample was received more than 24 hours after collection.”-Collected: 06/01/2025 08:00, Received: 06/02/2025
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  21. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample collected on Jan 31, 2025, shows the presence of total coliforms, and Pseudomonas aeruginosa- Treat the hot tub water and submit a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Bacteriological sample collected on Jan 31, 2025, resulted in 10,240 CFU/mL.- Treat the hot tub water and submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  22. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample collected on Jan 17, 2025, shows the presence of total coliforms. - Treat the hot tub water and submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  23. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  24. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample collected on Nov 15, 2024, shows the presence of total coliforms. - Treat the hot tub water and submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  25. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological sample collected on Aug 02, 2024, shows the presence of total coliforms. Please treat the hot tub.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  26. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 54 ppm. - Maintain total alkalinity between 60-180 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter did not appear to be working. - Repair or replace the flow meter.
  27. Demand Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured low at 34 ppm. - Maintain total alkalinity between 60-180 ppm. - Ensure that staff understand what adequate alkalinity level is and are adding enough sodium bicarbonate for optimal level.