MNP Community & Sport Centre - 20 Person Whirlpool

2225 Macleod Trail SE Calgary AB T2G 5B6 · Aquatic Facility

19 inspections

  1. Monitoring Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • **CORRECTED**1. One of the skimmer baskets was not secured in place. A staff member pushed the basket down in place during the inspection.
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The water sample collected on June 16, 2026 not tested, because there was no identification number on the bottle.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The combined chlorine measured 2.61ppm and there was a strong chlorine odour observed.COMPLETE THE FOLLOWING:1. Reduce the combined chlorine to the lowest level possible (recommended maximum is 1.00ppm). It is recommended to add more fresh water to the basin more often.
  3. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Water sample received by the lab on March 3 not tested. The date and time of collection was March 2 at 8:30am and the sample was received on March 3 at 11:42am.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The combined chlorine measured 2.61ppm and there was a strong chlorine odour observed.COMPLETE THE FOLLOWING:1. Reduce the combined chlorine to the lowest level possible (recommended maximum is 1.00ppm). It is recommended to add more fresh water to the basin more often.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample submitted on November 12, 2025 was not processed, because the sample was received more than 24 hours after collection. The date of the requisition form was November 10, 2025.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The combined chlorine measured 2.61ppm and there was a strong chlorine odour observed.COMPLETE THE FOLLOWING:1. Reduce the combined chlorine to the lowest level possible (recommended maximum is 1.00ppm). It is recommended to add more fresh water to the basin more often.
  5. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Pseudomonas Aeuginosa isolated in water sample collected on October 28, 2025. Operator to treat pool immediately.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Water sample collected on October 28, 2025 had a Heterotrophic Plate Count of 130 colony forming units/mL.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The combined chlorine measured 2.61ppm and there was a strong chlorine odour observed.COMPLETE THE FOLLOWING:1. Reduce the combined chlorine to the lowest level possible (recommended maximum is 1.00ppm). It is recommended to add more fresh water to the basin more often.
  6. Monitoring Inspection

    0 infractions

  7. Demand Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  9. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  10. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on March 4/25 was positive for Pseudomonas. - The whirlpool was drained and filled yesterday. The water will be superchlorinated today and resample submitted tomorrow.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  11. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  12. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on February 4/25 had HPC of 4680 cfu/ml. - Spoke with Owen who will superchlorinate and resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  13. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 2ppm. Ensure CCs are below 1 ppm.
  14. Demand Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorines measured 3ppm. Ensure CCs are below 1 ppm.
  15. Risk Management Inspection

    0 infractions

  16. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample for bacteriological analysis taken on 2024-02-27 was not processed as there was no identification on the bottle submitted. Please resample.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected and analyzed on 2023-11-14 shows the presence of Pseudomonas. Please treat the basin and submit in a re-sample.
  19. Monitoring Inspection

    0 infractions