MNP Community & Sport Centre - Cold Tub

2225 Macleod Trail SE Calgary AB T2G 5B6 · Aquatic Facility

13 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. The north skimmer was missing a skimming device.COMPLETE THE FOLLOWING:1. Install a floating weir or floating ring in the skimmer to ensure one way flow of water.
  3. Demand Inspection

    0 infractions

  4. Demand Inspection

    0 infractions

  5. Demand Inspection

    0 infractions

  6. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH of the pool was measured at 7.85, which can reduce the chlorine effectiveness. **Please ensure pH of the pool is maintained between 6.8 to 7.6 at all times.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 3.1 ppm.**Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Disparity noted between the automatic chemical feeder reading (pH: 7.2) and manual testing (pH: 7.85). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
  7. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 2.77ppm.- Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
  8. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample for bacteriological analysis taken on 2024-02-27 was not processed as there was no identification on the bottle submitted. Please resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 2.77ppm.- Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
  9. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 2.77ppm.- Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
  10. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected on 2024-02-13 shows the presence of total coliforms. Please treat the basin and re-sample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on 2024-02-13 shows the presence of HPC >57,000 cfu/ml. Please treat the basin and re-sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 2.77ppm.- Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
  11. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the cold tub measured at 2.77ppm.- Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The sample collected on September 23, 2023 was received more than 24 hours after collection.Resample.
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The sample collected on Sep 12, 2023, had an HPC count of 310 CFU/ml.Spoke with Ronie. Treat the basin, rebalance the chemistry, and send in a resample.