Wingate By Wyndham Calgary Airport - Whirlpool
57 Freeport Crescent NE Calgary AB T3J 0T4 · Aquatic Facility
Inspection summary
Wingate By Wyndham Calgary Airport - Whirlpool has been inspected 32 times by Alberta Health Services (Environmental Public Health) since October 31, 2023. The most recent inspection, on September 4, 2026, recorded 3 infractions.
None of the 32 inspections on record were free of infractions. In the past 12 months there were 3 inspections with 8 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 68 times across 32 separate inspections, most recently on September 4, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 5 times across 5 separate inspections, most recently on May 13, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
Permits, records and postingLower risk
Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.
Recorded 21 times across 21 separate inspections, most recently on September 4, 2026. For example:
Are proper testing, monitoring, and other records being properly maintained?
Food safety training and certificationLower risk
Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.
Recorded 8 times across 8 separate inspections, most recently on June 14, 2024. For example:
Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
32 inspections
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on September 2, 2026, was unsatisfactory with the presence of Pseudomonas aeruginosa.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (26ES-028E00275) collected on January 28th, 2026, came back unsatisfactory as the HPC was elevated (2960CFU/ml). Please resample the hot tub as soon as possible.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on September 24, 2025, was unsatisfactory with an HPC of 290 CFU/mL.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Repeat violation:Water sample collected on 17/09/2025, had a HPC of 400 CFU/ml.Previous violation:ID 25ES253E00372The water sample collected on September 10, 2025, had a HPC count of 140 CFU/mL. - Submit a re-sample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- ID 25ES253E00372The water sample collected on September 10, 2025, had a HPC count of 140 CFU/mL. - Submit a re-sample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on July 30, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on July 30, 2025, had a HPC count of 1200 CFU/mL. **Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on June 25, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on May 7, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on May 7, 2025, had a HPC count = 310 CFU/ml, which is higher than the required limit. **Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Disparity noted between the automatic chemical feeder reading (pH: 7.3) and manual testing (pH: 7.7). **Please calibrate the automatic feeder.**Compare readings from both automatic feeder and manual testing on regular basis for any inconsistencies.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Staff are not documenting corrective action when pool chemical parameters are not in the required range.**Ensure records for all corrective actions taken are maintained.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on May 7, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on May 7, 2025, had a HPC count = 310 CFU/ml, which is higher than the required limit. **Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine in the hot tub measured at 2.77 ppm.**Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine in the hot tub measured at 2.77 ppm.**Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on April 23, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on April 23, 2025, had a HPC count > 57000 CFU/ml, which is significantly higher than the required limit. **Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine in the hot tub measured at 2.77 ppm.**Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine in the hot tub measured at 2.77 ppm.**Please keep combined chlorine levels as low as possible for optimal comfort of bathers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- **Corrected**FAC measured 0.33 ppm as the chemical feeder was turned off. - Operator turned on the chemical feeder and FAC measured 6 ppm during inspection. **Ensure FAC in the whirlpool (> 30*C) is maintained at 2 ppm or above at all times. **Ensure chemical feeder is turned on at all times. ***Ensure chlorine is not added manually in the whirlpool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on March 26, 2025 had a HPC of 130 CFU.Please resample
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Due to error in sampling, no ID number was put on bottle and lab could not process. Resample must be processed immediately.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 15, 2025, had an HPC of 230 CFU/mL in the sample.REQUIREMENT: Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1) The water sample collected on August 14, 2024, had Pseudomonas isolated in the sample.2) The water sample collected on August 20, 2024, had Pseudomonas isolated in the sample.REQUIREMENT: Begin treatment for the swimming pool immediately; Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1) The water sample collected on August 14, 2024, had an HPC Count of >57000 CFU/mL.2) The water sample collected on August 20, 2024, had an HPC Count of 1480 CFU/mL.REQUIREMENT: Begin treatment for the swimming pool immediately; Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on August 14, 2024, had Pseudomonas isolated in the sample.REQUIREMENT: Begin treatment for the swimming pool immediately; Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on August 14, 2024, had an HPC Count of >57000 CFU/mL.REQUIREMENT: Begin treatment for the swimming pool immediately; Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **Ongoing violation** The flow rate of the swimming was 48 USGPM, which will achieve a turnover period of approximately 21 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on May 08, 2024, had total coliforms present in the sample.The water sample collected on May 15, 2024, had Pseudomonas isolated.REQUIREMENT: Close the whirlpool. Begin treatment for the pool. Collect and send a re-sample after you complete necessary treatments, and the water chemistry is balanced. Indicate on the requisition form that the sample is a ‘resample’.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on May 08, 2024, had total coliforms present in the sample.REQUIREMENT: Begin treatment for the pool. Collect and send a re-sample on Monday after you complete necessary treatments, and the water chemistry is balanced. Verify that correct sampling technique was conducted. Indicate on the requisition form that the sample is a ‘resample’.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The whirlpool water sample collected on February 21, 2024, showed that HPC was enumerated at 680 CFU/mL.-Please resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected around February 07, 2024, was not processed - the date and time of the collection was not provided on the requisition form.REQUIREMENT: Collect a new water sample and ensure the correct date is written on the requisition form.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
6 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on January 24, 2024, has Pseudomonas isolated in the sample.REQUIREMENT: Refer to the Pseudomonas sheet (sent via email) and begin treatment for the whirlpool immediately. Send a re-sample for the whirlpool after you complete necessary treatments.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 24, 2024 had an HPC count of 680 CFU/mL.REQUIREMENT: Refer to the section regarding Pseudomonas treatment.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate of the swimming was 45 USGPM, which will achieve a turnover period of 22 minutes.REQUIREMENT: To achieve the required < 20 minutes turnover period, ensure the flow rate is above 52 USGPM
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- **Ongoing Concern** A certified pool operator was not operating and maintaining the pool on a day-to-day basis.REQUIREMENT: A certified pool operator must monitor the swimming pool basin daily. Ensure enough owners, owner’s agents, and/or staff members are certified by an organization that is on the List of Approved Pool Operator Education Organizations approved by the Minister.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** There was no information to indicate when the submerged suction outlet covers were installed, and when they need to be replaced. Covers still appear properly secured and did not appear damaged.REQUIREMENT: Locate information detailing when the submerged suction outlet covers were installed, and when they need to be replaced. If this information cannot be located, promptly replace the covers.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- **Ongoing Violation** The anti-entrapment plan was missing or not available on-site.REQUIREMENT: Reassess the swimming pool for all entrapment risks, and develop, implement, and maintain an anti-entrapment plan. Submit the plan to an Executive Officer with Environmental Public Health for review.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Nearby inspected facilities
- Wingate By Wyndham Calgary Airport - Common
57 Freeport Crescent NE Calgary AB T3J 0T4
3 inspections
- Wingate by Wyndham Calgary Airport - Food
57 Freeport Crescent NE Calgary AB T3J 0T4
2 inspections
- Wingate By Wyndham Calgary Airport - Swimming Pool
57 Freeport Crescent NE Calgary AB T3J 0T4
30 inspections
- Holiday Inn Express & Suites - Whirlpool
41 Freeport Crescent NE Calgary AB T3J 0T4
20 inspections
- Holiday Inn Express & Suites - Swimming Pool
41 Freeport Crescent NE Calgary AB T3J 0T4
16 inspections
- Holiday Inn Express & Suites - Food
41 Freeport Crescent NE Calgary AB T3J 0T4
3 inspections
- Holiday Inn Express & Suites - Common
41 Freeport Crescent NE Calgary AB T3J 0T4
6 inspections
- Planet Coffee
24 - 56 Freeport Crescent NE Calgary AB T3J 0T7
1 inspection