Skip to content
Loading map…

Comfort Inn & Suites by Calgary Airport North - Swimming Pool

147 Freeport Crescent NE Calgary AB T3J 0T3 · Aquatic Facility

18 inspections

  1. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample (26ES-184E00216) collected on July 2, 2026, was unsatisfactory. HPC was elevated (420 CFU/ml).Please treat and resample
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  3. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on April 2, 2026, was not tested because the water sample was received more than 24 hours after collection.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  5. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  6. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on March 26, 2026, was unsatisfactory with an HPC of 120 CFU/mL.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  7. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  8. Demand Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate was measured at 47.5 GPM. The minimum flow rate required to achieve the required 4-hour turnover period is 57.4 GPM. Please ensure that the flow rate is maintained between 57.4 and 73.5 GPM.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. Operator pool certification expired in April 2024. Swimming pool must be maintained by a certified pool operator.**OUTSTANDING (2026-03-03). The pool operator was scheduled to take a pool operator course this March 24. Once the course is completed, please provide a copy of the certificate to the Executive Officer.
  9. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine measured at 1.67 ppm. **Ensure combined chlorine are maintained as low as possible at all times for maximum user comfort.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Outstanding**The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. - Operator pool certification expired in April 2024. **Swimming pool must be maintained by a certified pool operator.
  10. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Update July 2, 2025Total alkalinity measured 28 ppm. Update June 27, 2025 Total alkalinity in the pool measured 0 ppm. - Operator raised the total alkalinity to 51 ppm. **Ensure total alkalinity is maintained between 60 ppm and 180 ppm at all times.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Outstanding**The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. - Operator pool certification expired in April 2024. **Swimming pool must be maintained by a certified pool operator.
  11. Monitoring Inspection

    5 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine in the pool measured 1.79 ppm. **Ensure combined chlorine is maintained as low as possible.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity in the pool measured 0 ppm. - Operator raised the total alkalinity to 51 ppm. **Ensure total alkalinity is maintained between 60 ppm and 180 ppm at all times.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated feeder display for pH was not consistent with manual tests; the display for pH was 7.3, whereas the inspector tested the pH at 6.8.**Please calibrate the probe.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Outstanding**The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • There is no person who is currently certified to operate the swimming pool. - Operator pool certification expired in April 2024. **Swimming pool must be maintained by a certified pool operator.
  12. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on August 01, 2024, had an HPC count of 240 CFU/mL.REQUIREMENT: Please review the water chemistry and begin treatment for the pool. Collect and send a re-sample after you complete necessary treatments and when the water chemistry is balanced. Indicate on the requisition form that the sample is a ‘resample’
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
  13. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
  14. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on April 04, 2024 had an HPC count of >57000 CFU/mL.REQUIREMENT: Review the water chemistry and immediately treat the water. Review water sampling technique to ensure that the sample wasn't accidentally contaminated. Send in a resample once treatments are complete and water chemistry is balanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was tested and measured to be 51 ppm.REQUIREMENT: Maintain the total alkalinity between 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The pool basin is significantly degraded and damaged in an area close to the ladder and skimmer in the deep end. This issue reportedly started 1-2 months ago. Water is entering through the exposed portion behind the wall meaning chlorinated water will not circulate through this area effectively, and as a result, the risk of bacteriological growth has significantly increased.REQUIREMENT: Repair any damaged sections and replace any water damaged components. Ensure the water is drained from the wall.
  15. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on March 07, 2024, was not processed. The date/time of sample collection was later than the date of receipt.REQUIREMENT: Submit another water sample and ensure the paperwork is properly filled out.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was tested and measured to be 51 ppm.REQUIREMENT: Maintain the total alkalinity between 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The pool basin is significantly degraded and damaged in an area close to the ladder and skimmer in the deep end. This issue reportedly started 1-2 months ago. Water is entering through the exposed portion behind the wall meaning chlorinated water will not circulate through this area effectively, and as a result, the risk of bacteriological growth has significantly increased.REQUIREMENT: Repair any damaged sections and replace any water damaged components. Ensure the water is drained from the wall.
  16. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was tested and measured to be 51 ppm.REQUIREMENT: Maintain the total alkalinity between 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate is too fast and exceeds the maximum rate of filtration.It appears that the filter has changed within the last two years, as previous reports/notes indicated a filter that had a larger effective filtration area (4.9 sq. ft).REQUIREMENT: Replace the Tagelus TA-100D filter with a filter with a larger square footage (> 4.4 sq. ft).
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • The pool basin is significantly degraded and damaged in an area close to the ladder and skimmer in the deep end. This issue reportedly started 1-2 months ago. Water is entering through the exposed portion behind the wall meaning chlorinated water will not circulate through this area effectively, and as a result, the risk of bacteriological growth has significantly increased.REQUIREMENT: Repair any damaged sections and replace any water damaged components. Ensure the water is drained from the wall.
  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on August 31, 2023 was not processed due to no identification number on the submitted bottle.REQUIREMENT: Send in another sample and ensure the sticker on the form is included on the bottle.
  18. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on August 10, 2023, had HPC detected at >57000 CFU/mL.REQUIREMENT: Review the water chemistry for the pool and balance as needed. An immediate re-sample is not required for the swimming pool at this time.