Edmonton Hotel and Convention Centre - Whirlpool
4520 76 Avenue NW Edmonton AB T6B 0A5 · Aquatic Facility
18 inspections
- Monitoring Inspection
2 infractions
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was 41.5C. Adjust the thermostat to ensure the water temperature is at or below 40C.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical tests for the whirlpool were not documented for this week. Operator is covering for their second maintenance person who is away. Ensure that testing is conducted daily and documented. This should include the visual checks of the main drain covers which was not being done consistently.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 26 Sept 2025 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 26 Sept 2025 was unsatisfactory: HPC 3270 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 10 July 2025 was unsatisfactory: HPC 120CFU/mL. No water samples were collected for the week of June 30 - July 6, 2025. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 10 July 2025 was unsatisfactory: HPC 120CFU/mL. No water samples were collected for the week of June 30 - July 6, 2025. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan must be updated to reflect the replacement of the main drains in the whirlpool. Forward a copy to the undersigned for review.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- ORP was high and free chlorine was only able to be maintained at 1.47ppm. Operator advised to clean probes and monitor to ensure the system can maintain a reasonable free chlorine level. Continue to monitor and service system as necessary.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan must be updated to reflect the replacement of the main drains in the whirlpool. Forward a copy to the undersigned for review.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The free chlorine measured in the whirlpool was 0.48ppm. Adjust the free chlorine to be at least1.0ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool temperature is 41.6C. Operator adjusted thermostat to ensure temperature does not exceed 40C.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan must be updated to reflect the replacement of the main drains in the whirlpool. Forward a copy to the undersigned for review.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pH value tested (7.46) and the pH reading from the chemical controller (7.3) are not consistent. Check the chemical controller and make the necessary repairs and/or adjustments to ensure the system is consistent with manual readings.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan must be updated to reflect the replacement of the main drains in the whirlpool. Forward a copy to the undersigned for review.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 11/10/2024 was unsatisfactory: HPC 1410 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on [Date] was unsatisfactory: HPC 1540 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free chlorine was <1ppm for the whirlpool. Operator noted that fresh water was recently added to the basin and the controller was not feeding yet. Advised operator to check and adjust set points as necessary to ensure adequate chlorine concentration.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow meter was not working when pump was running. Replace the flow meter as the top of flow meter was damaged.2. Chemical injection port appears to be repaired and clamped to prevent leaking. Permanently replace the injection plumbing to prevent further leaking.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was at 42.8C. Operator adjusted the thermostat to ensure temperature is at or less than 40C.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 13 May 2024 was unsatisfactory:, Total Coliform present. Take all necessary action to ensure microbiologically safe water.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 13 May 2024 was unsatisfactory: HPC 2170 CFU/mL. Take all necessary action to ensure microbiologically safe water. Microbiological water samples have not been submitted since April 24, 2024
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow meter was not working when pump was running. Replace the flow meter as the top of flow meter was damaged.2. Chemical injection port appears to be repaired and clamped to prevent leaking. Permanently replace the injection plumbing to prevent further leaking.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was at 42.8C. Operator adjusted the thermostat to ensure temperature is at or less than 40C.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow meter was not working when pump was running. Replace the flow meter as the top of flow meter was damaged.2. Chemical injection port appears to be repaired and clamped to prevent leaking. Permanently replace the injection plumbing to prevent further leaking.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool water temperature was at 42.8C. Operator adjusted the thermostat to ensure temperature is at or less than 40C.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 19 April 2024 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 19 April 2024 was unsatisfactory: HPC 240 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 21 Sept 2023 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?