Skip to content
Loading map…

Pomeroy Hotel & Conference Centre - Swimming Pool

11633 100 Street Grande Prairie AB T8V 3Y4 · Aquatic Facility

Inspection summary

Pomeroy Hotel & Conference Centre - Swimming Pool has been inspected 11 times by Alberta Health Services (Environmental Public Health) since October 18, 2023. The most recent inspection, on February 18, 2026, recorded 1 infraction.

4 of 11 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 8 times across 6 separate inspections, most recently on February 18, 2026. For example: Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on October 18, 2023. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

11 inspections

  1. Risk Management Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The pool has a single blockable submerged outlet and a secondary anti-entrapment device has not been employed. Update:A plan is in place to get an unblockable submerged outlet installed in the spring
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count: 560 cfu/ml** Ensure water chemistry is within operating parameters and resample on the next sampling day.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The pool has a single blockable submerged outlet and a secondary anti-entrapment device has not been employed. Update:A plan is in place to get an unblockable submerged outlet installed in the spring
  3. Demand Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The pool has a single blockable submerged outlet and a secondary anti-entrapment device has not been employed. ** Ensure to review secondary anti-entrapment options with a professional engineer. Options include:- Safety Vacuum Release System (SVRA)- Automatic pump shut off- Suction-limiting vent system- Permanently disable the single outlet. Verify that the overflow and skimmers are capable of handling the required system flow and that minimum turnover rates are achieved- A gravity flow system able to safely limit suction- Convert single suction outlet to return outlet by changing the piping, provided that the system piping and skimmer(s) are capable of handling the full system flowMain drain was turned off during visit and skimmers were capable of handling system flow and minimum turnover rate was not affected. Please ensure this secondary anti-entrapment method is verified by a professional engineer or if another method is better suited for the system
  4. Monitoring Inspection

    0 infractions

  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample result was unsatisfactory, HPC = 1530cfu/ml- Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance water chemistry and resample.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample result was unsatisfactory, HPC = 3660cfu/ml- Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance water chemistry and resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Last bacteriological water sample was submitted on Dec 9.- ensure bacteriological water samples are submitted weekly.
  9. Risk Management Inspection

    0 infractions

  10. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample result was unsatisfactory, HPC =260cfu/ml Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water, resample as soon as posible.
  11. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Automated Controller reading;ORP- 696pH - 7.21PHI reading;pH - 7.2FAC- 0.84C.C - 0.28T.A - 115 Ensure FAC is maintained at a minimum of 1ppm or ORP at a minimum of 700.

Nearby inspected facilities

Own this business? Add a badge to your website