Pomeroy Hotel & Conference Centre - Whirlpool
11633 100 Street Grande Prairie AB T8V 3Y4 · Aquatic Facility
Inspection summary
Pomeroy Hotel & Conference Centre - Whirlpool has been inspected 11 times by Alberta Health Services (Environmental Public Health) since October 18, 2023. The most recent inspection, on July 14, 2026, found no infractions.
6 of 11 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 7 times across 5 separate inspections, most recently on June 12, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
11 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on June 9, 2026.HPC: >57,000 CFU/mL.Ensure HPC is less than 100 CFU/mL.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on June 2, 2026.HPC: 280 CFU/mL.Ensure HPC is less than 100 CFU/mL.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample result was unsatisfactory indicating the presence of Pseudomonas aeruginosa.- Backwash and increase Free Available Chlorine (FAC) to 10 ppm and lower the pH to 6.8 - 7.0. Run the water through the circulation system for at least one turnover.Completely drain the whirlpool, scrub the whirlpool pool surfaces with acid or sanitizer, rinse off acid/sanitizer and refill the pool. Adjust water chemistry to regular operating parameters and submit a new water sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample result was unsatisfactory indicating the presence of Pseudomonas aeruginosa.- Backwash and increase Free Available Chlorine (FAC) to 10 ppm and lower the pH to 6.8 - 7.0. Run the water through the circulation system for at least one turnover.Completely drain the whirlpool, scrub the whirlpool pool surfaces with acid or sanitizer, rinse off acid/sanitizer and refill the pool. Adjust water chemistry to regular operating parameters and submit a new water sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample result was unsatisfactory, HPC = 520cfu/ml- Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance water chrmistry water and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Last bacteriological water sample was submitted on Dec 6- ensure bacteriologicsl water samples are submitted weekly.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Hot tub volume is 3650 liters (3.65 cubic meters, 964.3G ).Flow rate - 55 GPMTurnover = 964.3/55= 17.5 minutesEnsure the turnover rate is maintained at 15 minutes or less.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Nearby inspected facilities
- Pomeroy Hotel & Conference Centre - Event
11633 100 Street Grande Prairie AB T8V 3Y4
1 inspection
- Pomeroy Hotel & Conference Centre - The Office and Skylark Lounge
11633 100 Street Grande Prairie AB T8V 3Y4
7 inspections
- Pomeroy Hotel & Conference Centre - Aquatic Common Area
11633 100 Street Grande Prairie AB T8V 3Y4
5 inspections
- Pomeroy Hotel & Conference Centre - Swimming Pool
11633 100 Street Grande Prairie AB T8V 3Y4
11 inspections
- Silver Crest Lodge - Food
11902 100 Street Grande Prairie AB T8V 4H5
5 inspections
- Tim Hortons 1785
11740 100 Street Grande Prairie AB T8V 4H5
5 inspections
- McDonald's 4895
11802 100 Street Grande Prairie AB T8V 4H5
7 inspections
- Anavada Inn & Suites
11724 100 Street Grande Prairie AB T8V 4H5
1 inspection