Hampton Inn By Hilton Edmonton South - Whirlpool
10020 12 Avenue SW Edmonton AB T6X 0P6 · Aquatic Facility
Inspection summary
Hampton Inn By Hilton Edmonton South - Whirlpool has been inspected 15 times by Alberta Health Services (Environmental Public Health) since October 30, 2023. The most recent inspection, on April 20, 2026, recorded 3 infractions.
None of the 15 inspections on record were free of infractions. In the past 12 months there were 4 inspections with 13 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Food temperature control.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 35 times across 15 separate inspections, most recently on April 20, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 5 times across 5 separate inspections, most recently on January 16, 2025. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
15 inspections
- Risk Management Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have not been installed during current inspection. Operations manager stated they can no longer get the direct replacement inlets but will have to speak with the supplier to determine what can be installed instead.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Previously noted leak was repaired however another leak was noted on the elbow just above the flow meter. Repair or replace the plumbing as required.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The skimmer pot lid on the SW corner of the tub was cracked and had a hole in it. Replace the lid as the sharp edges could be a injury hazard to patrons.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 10 April 2026 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 10 April 2026 was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have not been installed during current inspection. Operations manager stated they can no longer get the direct replacement inlets but will have to speak with the supplier to determine what can be installed instead.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Previously noted leak was repaired however another leak was noted on the elbow just above the flow meter. Repair or replace the plumbing as required.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The skimmer pot lid on the SW corner of the tub was cracked and had a hole in it. Replace the lid as the sharp edges could be a injury hazard to patrons.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have not been installed during current inspection. Operations manager stated they can no longer get the direct replacement inlets but will have to speak with the supplier to determine what can be installed instead.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Previously noted leak was repaired however another leak was noted on the elbow just above the flow meter. Repair or replace the plumbing as required.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The skimmer pot lid on the SW corner of the tub was cracked and had a hole in it. Replace the lid as the sharp edges could be a injury hazard to patrons.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have not been installed during current inspection
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The potable water fill line connected to the circulation pump was leaking while the operator was using it to prime the pump. Repair the leaking water fill line connection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 15/08/2025 was unsatisfactory: Pseudomonas aeruginosa isolated, Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 15/08/2025 was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Main drains in the whirlpool have expired. Facility is awaiting replacement parts from pool service provider. Whirlpool is closed to patrons until the main drains are replaced and compliant.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Rigid PVC schedule 80 pipes from the filter to the heater appeared to be warped and discolored. Facility management stated that they had a heater issue and are planning to replace them. The flow meter appeared to be damaged and was not returning to zero when the pump was turned off. Repair and replaced damaged piping.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sections of the basin tile are missing and require repair. Repair damaged and missing tiles.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 2 Jan 2025 was unsatisfactory: Pseudomonas aeruginosa isolated, Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on [Date] was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Rigid PVC schedule 80 pipes from the filter to the heater appeared to be warped and discolored. Facility management stated that they had a heater issue and are planning to replace them. The flow meter appeared to be damaged and was not returning to zero when the pump was turned off. Repair and replaced damaged piping.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sections of the basin tile are missing and require repair. Repair damaged and missing tiles.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Rigid PVC schedule 80 pipes from the filter to the heater appeared to be warped and discolored. Facility management stated that they had a heater issue and are planning to replace them. The flow meter appeared to be damaged and was not returning to zero when the pump was turned off. Repair and replaced damaged piping.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sections of the basin tile are missing and require repair. Repair damaged and missing tiles.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin. Inlets have been purchased and are to be installed after grouting.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 2024-02-16 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 2024-02-16 was unsatisfactory: HPC 390 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- A section of tiles are missing in the basin by the bottom of the stairs. Repair or replace this to prevent injury and/or further deterioration.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 27 Oct 2023 was unsatisfactory: HPC 1950 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The return inlets for the jets and the circulation system in the foot well were missing throughout the basin. Install proper eyeball fittings to ensure proper water circulation occurs in the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- A section of tiles are missing in the basin by the bottom of the stairs. Repair or replace this to prevent injury and/or further deterioration.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Nearby inspected facilities
- Hampton Inn By Hilton Edmonton South - Swimming Pool
10020 12 Avenue SW Edmonton AB T6X 0P6
7 inspections
- Hampton Inn By Hilton Edmonton South - Common Area
10020 12 Avenue SW Edmonton AB T6X 0P6
3 inspections
- Four Points by Sheraton Edmonton Gateway - Common Area
10010 12 Avenue SW Edmonton AB T6X 0P9
7 inspections
- Four Points by Sheraton Edmonton Gateway - Swimming Pool
10010 12 Avenue SW Edmonton AB T6X 0P9
5 inspections
- Four Points by Sheraton Edmonton Gateway - Whirlpool
10010 12 Avenue SW Edmonton AB T6X 0P9
10 inspections
- Hunney Lashes
10010 12 Avenue SW Edmonton AB T6X 0P9
2 inspections
- Central Social Hall
10014 12 Avenue SW Edmonton AB T6X 0P9
1 inspection
- Denny's / Bar One
10111 Ellerslie Road SW Edmonton AB T6X 0J3
7 inspections